Evidence map›Paper›PMID 35139843›Full record

ArticleBMC musculoskeletal disorders2022

Biomechanics of extreme lateral interbody fusion with different internal fixation methods: a finite element analysis.

Xiao-Hua Li, Li-Jun She, Wei Zhang, Xiao-Dong Cheng, Jin-Peng Fan

Abstract read
In one paragraph

Article in BMC musculoskeletal disorders, 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 10 papers.

0numbers the graph read from it
0cells of the map it votes in
10citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

10 citing papers in PubMed.

  1. Article
  2. Article
  3. Article
  4. Article
  5. Article
  6. Article
  7. Article
  8. Article
  9. Article
  10. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors.

Xiao-Hua LiDepartment of Spinal Surgery, The Third Hospital of Hebei Medical University, No. 139 Ziqiang Road, Shijiazhuang, 050051, China.
Li-Jun SheDepartment of Tuberculosis, The Fifth Hospital of Shijiazhuang, No.42 Tanan Road, Shijiazhuang, 050000, China.
Wei ZhangDepartment of Spinal Surgery, The Third Hospital of Hebei Medical University, No. 139 Ziqiang Road, Shijiazhuang, 050051, China. sjzsdyyy@yeah.net.
Xiao-Dong ChengDepartment of Spinal Surgery, The Third Hospital of Hebei Medical University, No. 139 Ziqiang Road, Shijiazhuang, 050051, China.
Jin-Peng FanDepartment of Orthopedic Surgery, Shijiazhuang First Hospital, No. 365 Jianhua South Street, Shijiazhuang, 050000, China.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

backgroundEstablishing a normal L3-5 model and using finite element analysis to explore the biomechanical characteristics of extreme lateral interbody fusion (XLIF) with different internal fixation methods.

methodThe L3-5 CT image data of a healthy adult male volunteer were selected to establish a normal lumbar finite element model (M0). The range of motion (ROM) of L3-4 and L4-5, under flexion, extension, left bending, right bending, left rotation, and right rotation, together with L3-4 disc pressure was analyzed. Then the L4-5 intervertebral disc was excised and implanted with a cage, supplemented by different types of internal fixation, including lateral two-hole plate model (M1), lateral four-hole plate model (M2), VerteBRIDGE plating model (M3), lateral pedicle model (M4), posterior unilateral pedicle screw model (M5) and posterior bilateral pedicle screw model (M6). The ROM,the maximum stress value of the cage, and the maximum stress value of the intervertebral disc of L3-4 were analyzed and studied .

resultsThe ROM of L3-4 and L4-L5 segments in the validation model under various motion states was basically consistent with previous reports. The lumbar finite element model was validated effectively. After XLIF-assisted internal fixation, the range of activity in L3-4 segments of each internal fixation model was greater than that of the normal model under various working conditions, among which the M5、M6 model had the larger range of activity in flexion and extension. After the internal fixation of L4-5 segments, the mobility in M1-M6 was significantly reduced under various motion patterns. In terms of flexion and extension, the posterior pedicle fixation model (M5、M6) showed a significant reduction,followed by M2. The maximal von mises cage stress of M1 was obviously greater than that of other models (except the left bending). Compared with M0, the intervertebral disc stress of M1-M6 at L3-4 segments was increased.

conclusionsIt is recommended that the posterior bilateral pedicle screw model is the first choice, followed by the lateral four-hole plate model for fixation during XLIF surgery. However, it is still necessary to be aware of the occurrence of adjacent segment degeneration (ASD) in the later stage.

Indexed as

Pedicle ScrewsSpinal FusionAdultBiomechanical PhenomenaFinite Element AnalysisHumansLumbar VertebraeMaleRange of Motion, ArticularAdjacent segment degenerationCage subsidenceExtreme lateral interbody fusionFinite element analysisInternal fixation

Identifiers

PMID35139843
PMCPMC8829978

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.