Evidence map›Paper›PMID 35138887›Full record

ArticleScience advances2022

A 4D x-ray computer microtomography for high-temperature electrochemistry.

Handong Jiao, Zhaoliang Qu, Shuqiang Jiao, Yang Gao, Shijie Li, Wei-Li Song, Haosen Chen, Hongmin Zhu, Rongqi Zhu, Daining Fang

Open access · goldAbstract read
In one paragraph

Article in Science advances, 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 4 papers.

0numbers the graph read from it
0cells of the map it votes in
4citing papers in PubMed
2.2field-weighted citation impact, top 13% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

4 citing papers in PubMed, 28 citations in OpenAlex.

  1. Article
  2. Article
  3. Article
  4. Operando probing and adjusting of the complicated electrode process of multivalent metals at extreme temperature.Proceedings of the National Academy of Sciences of the United States of America · 2023
    Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

10 authors at 4 institutions in 2 countries.

Handong JiaoInstitute of Advanced Structure Technology, Beijing Institute of Technology, Beijing 100081, PR China.ORCID 0000-0001-8029-0906
Zhaoliang QuInstitute of Advanced Structure Technology, Beijing Institute of Technology, Beijing 100081, PR China.ORCID 0000-0002-8789-294X
Shuqiang JiaoInstitute of Advanced Structure Technology, Beijing Institute of Technology, Beijing 100081, PR China.ORCID 0000-0001-9600-752X
Yang GaoState Key Laboratory of Advanced Metallurgy, University of Science and Technology Beijing, Beijing 100083, PR China.
Shijie LiInstitute of Advanced Structure Technology, Beijing Institute of Technology, Beijing 100081, PR China.
Wei-Li SongInstitute of Advanced Structure Technology, Beijing Institute of Technology, Beijing 100081, PR China.ORCID 0000-0002-4328-8919
Haosen ChenInstitute of Advanced Structure Technology, Beijing Institute of Technology, Beijing 100081, PR China.
Hongmin ZhuTohoku University, 6-6-02, Aramaki-Aza-Aoba, Aobo-ku, Sendai 980-8579, Japan.ORCID 0000-0001-9747-4533
Rongqi ZhuCollege of Engineering, Peking University, Beijing 100871, PR China.
Daining FangInstitute of Advanced Structure Technology, Beijing Institute of Technology, Beijing 100081, PR China.ORCID 0000-0001-7122-8780
Beijing Institute of Technology · CNPeking University · CNTohoku University · JPUniversity of Science and Technology Beijing · CN

Funding

Nicotinic Receptors and SchizophreniaI01CX001021 · VA · VA EASTERN COLORADO HEALTH CARE SYSTEM · PI FREEDMAN, ROBERT · 2016 to 2016
–
CSRD VA I01 CX001021
6 · The paper itself

Abstract

High-temperature electrochemistry is widely used in many fields. However, real-time observations and an in-depth understanding of the inside evolution of this system from an experimental perspective remain limited because of harsh reaction conditions and multiphysics fields. Here, we tackled this challenge with a high-temperature electrolysis facility developed in-house. This facility permits in situ x-ray computer microtomography (μ-CT) for nondestructive and quantitative three-dimensional (3D) imaging. In an electrorefining system, the μ-CT probed the dynamic evolution of 3D morphology and components of electrodes (4D). Subsequently, this 4D process was visually presented via reconstructed images. The results monitor the efficiency of the process, explore the dynamic mechanisms, and even offer real-time optimization. This 4D analysis platform is notable for in-depth combinations of traditional electrochemistry with digital twin technologies owing to its multiscale visualization and high efficiency of data extraction.

Identifiers

PMID35138887
PMCPMC8827660
OpenAlexW4211105436

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.