ArticlePharmaceutical research2022
Assessment of High-Power Electronic Nicotine Delivery System as an Alternative Aerosol Device for Terbutaline Delivery.
Article in Pharmaceutical research, 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
2 citing papers in PubMed, 10 citations in OpenAlex.
- The Ability of Vaping Technology to Deliver an Equivalent Respirable Dose of Beclomethasone Dipropionate Compared to Nebulization.Pharmaceutics · 2024Article
- Development of a Novel Bronchodilator Vaping Drug Delivery System Based on Thermal Degradation Properties.Pharmaceuticals (Basel, Switzerland) · 2023Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
5 authors at 2 institutions in 1 country.
Funding
No grant is acknowledged in the PubMed record.
Abstract
purposeThe performance of new-generation high-power electronic nicotine delivery system (ENDS) for the administration of inhaled terbutaline was assessed.
methodsThe formulation of e-liquid was carried out using terbutaline in combination with 1, 3- propanediol. Several terbutaline concentrations (from 0.3125 to 2.500 mg / mL) and power levels (from 15 to 35 W) were assessed using a box type ENDS. The respirable drug dose was determined using a Glass Twin Impinger and quantified by liquid chromatography coupled with a UV-detector. The Next Generation Impactor and the Dekati Low Pressure Impactor were used to measure the aerosol particle size distribution in drug mass. The results were compared with a jet nebulizer (Cirrus TM 2) similar to the usual clinical conditions (2 mL at [terbutaline] of 2.5 mg / mL).
resultsThe optimal conditions to maximize terbutaline delivery using ENDS are a drug concentration at 1 mg/mL, and a power level at 30 W, to reach a respirable dose of 8.73 ± 0.90 µg/puff. By contrast, during a 5 min nebulization, the respirable dose of terbutaline was 1040 ± 33 µg whatever the cascade impactors and the aerosol devices used. The mass median aerodynamic diameter (MMAD) remains similar for jet nebulizer and ENDS in the 1.74-2.07 µm range.
conclusionCompared to the jet nebulizer, a same respirable dose of terbutaline at the same range of aerosol size distribution was delivered by ENDS if 120 puffs were performed. The ENDS can be considered as an alternative aerosol device for terbutaline delivery.