Reducing airborne infection risk of COVID-19 by locating air cleaners at proper positions indoor: Analysis with a simple model.

Hui Dai, Bin Zhao

Open access · greenAbstract read
In one paragraph

Article in Building and environment, 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 11 papers.

0numbers the graph read from it
0cells of the map it votes in
11citing papers in PubMed
8.4field-weighted citation impact, top 2% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

11 citing papers in PubMed, 57 citations in OpenAlex.

  1. Article
  2. Review
  3. Article
  4. Review
  5. Article
  6. Article
  7. Article
  8. Article
  9. Article
  10. Article
  11. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

2 authors at 1 institution in 1 country.

Hui DaiDepartment of Building Science, School of Architecture, Tsinghua University, Beijing, 100084, China.
Bin ZhaoDepartment of Building Science, School of Architecture, Tsinghua University, Beijing, 100084, China.
Tsinghua University · CN

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Portable air cleaners (PACs) can remove airborne SARS-CoV-2 exhaled by COVID-19 infectors indoor. However, effectively locating PAC to reduce the infection risk is still poorly understood. Here, we propose a simple model by regressing an equation of seven similarity criteria based on CFD-modeled results of a scenario matrix of 128 cases for office rooms. The model can calculate the mean droplet nucleus concentration with very low computing costs. Combining this model with the Wells-Riley equation, we estimate the airborne infection risk when a PAC is located in different positions. The two similarity criteria,

Indexed as

Air cleanerCOVID-19Infection probabilitySARS-CoV-2Wells–riley equation

Identifiers

PMID35136279
PMCPMC8813770
OpenAlexW4212858492

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.