Evidence map›Paper›PMID 35128975›Full record

ArticleJournal of diabetes science and technology2023

Safety and Effectiveness of the Use of an Electronic Glucose Monitoring System Versus Weight-Based Dosing Nomogram for Treatment of Diabetic Ketoacidosis and Hyperglycemic Hyperosmolar Syndrome in a VA Hospital.

Madeline Brown, Justin Roberts, Cole Smith, Dakota Eash

Open access · greenAbstract read
In one paragraph

Article in Journal of diabetes science and technology, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper, 1 of them a synthesis that pooled it.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed, 1 pooled it
0.1field-weighted citation impact, top 54% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed, 1 synthesis or guideline pooled it, 1 citations in OpenAlex.

  1. Pooled it
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

4 authors at 1 institution in 1 country.

Madeline BrownVeteran Health Indiana, Indianapolis, IN, USA.ORCID 0000-0001-5314-6175
Justin RobertsVeteran Health Indiana, Indianapolis, IN, USA.
Cole SmithVeteran Health Indiana, Indianapolis, IN, USA.
Dakota EashVeteran Health Indiana, Indianapolis, IN, USA.
Indiana University Health · US

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

objectiveThe objective of this study is to assess the safety and effectiveness of an electronic glucose monitoring system (eGMS) versus paper-based protocols (PBPs) to manage diabetic ketoacidosis (DKA) and hyperglycemic hyperosmolar syndrome (HHS) within the VA setting.

methodsThis study is a retrospective chart review of patients on an insulin drip, treated in the emergency department (ED) or intensive care unit (ICU) at Veteran Health Indiana for DKA or HHS. The primary outcome was evaluating the percentage of patients with hypoglycemia (blood glucose [BG] level <70 mg/dL) in patients admitted with DKA and HHS comparing an eGMS versus a PBP. A total of 168 patients were included in the analysis, with 84 patients in each group.

resultsThe primary outcome comparing rates of hypoglycemia in the eGMS group versus the PBP group showed a lower rate of hypoglycemia in the eGMS group (0.024%) compared with the PBP group (0.060%); however, this difference was not found to be statistically significant (

conclusionsWhile the primary endpoint of decreased hypoglycemia was not found to be statistically significant, it did reduce the overall number of hypoglycemia events in the eGMS group compared with the PBP group which may be clinically significant. This demonstrates that eGMS use has the potential to minimize hypoglycemia and glycemic variability in a critically-ill Veteran population by individualizing insulin drip titration based on a variety of patient-specific factors and providing reminders for staff to obtain BG checks in a timely manner.

Indexed as

Diabetes MellitusDiabetic KetoacidosisHyperglycemic Hyperosmolar Nonketotic ComaHypoglycemiaBlood GlucoseBlood Glucose Self-MonitoringGlucoseHospitalsHumansInsulinNomogramsRetrospective StudiesBlood GlucoseGlucoseInsulinDKAeGMSEndoToolHHShypoglycemiapaper-based protocol

Identifiers

PMID35128975
PMCPMC10210101
OpenAlexW4210876822