ArticleJournal of rehabilitation and assistive technologies engineering
Exploring textile-based electrode materials for electromyography smart garments.
Article in Journal of rehabilitation and assistive technologies engineering. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 14 papers, 1 of them a synthesis that pooled it.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
14 citing papers in PubMed, 1 synthesis or guideline pooled it.
- A Systematic Review of Design of Electrodes and Interfaces for Non-Contact and Capacitive Biomedical Measurements: Terminology, Electrical Model, and System Analysis.Sensors (Basel, Switzerland) · 2026Pooled it
- Key factors influencing children's cooperation during electromyography: a correlation analysis of Age, gender, and pain management.Frontiers in pediatrics · 2026Article
- Biointegrated Conductive Hydrogel for Real-Time Motion Sensing in Exoskeleton-Assisted Lower-Limb Rehabilitation.Sensors (Basel, Switzerland) · 2025Article
- A body-scale textile-based electromyogram monitoring system with coaxially shielded conductive yarns.Science advances · 2025Article
- Electromyography Signal Acquisition, Filtering, and Data Analysis for Exoskeleton Development.Sensors (Basel, Switzerland) · 2025Review
- Feasibility assessment of textile electromyography sensors for a wearable telehealth biofeedback system.Wearable technologies · 2025Article
- Minimization of Parasitic Capacitance between Skin and Ag/AgCl Dry Electrodes.Micromachines · 2024Article
- Design, Fabrication, and Evaluation of 3D Biopotential Electrodes and Intelligent Garment System for Sports Monitoring.Sensors (Basel, Switzerland) · 2024Article
- Benchtop Performance of Novel Mixed Ionic-Electronic Conductive Electrode Form Factors for Biopotential Recordings.Sensors (Basel, Switzerland) · 2024Article
- Integrating Wearable Textiles Sensors and IoT for Continuous sEMG Monitoring.Sensors (Basel, Switzerland) · 2024Article
- Evaluation of Novel Embroidered Textile-Electrodes Made from Hybrid Polyamide Conductive Threads for Surface EMG Sensing.Sensors (Basel, Switzerland) · 2023Article
- Human Arm Workout Classification by Arm Sleeve Device Based on Machine Learning Algorithms.Sensors (Basel, Switzerland) · 2023Article
- Fabrication of Textile-Based Dry Electrode and Analysis of Its Surface EMG Signal for Applying Smart Wear.Polymers · 2022Article
- Sialic acid biosensing by post-printing modification of PEDOT:PSS with pyridylboronic acid.Science and technology of advanced materials · 2022Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
7 authors.
Funding
No grant is acknowledged in the PubMed record.
Abstract
introductionIn recent years, electromyography (EMG) has been increasingly studied for wearable applications. Conventional gel electrodes for electrophysiological recordings have limited use in everyday applications such as prosthetic control or muscular therapy at home. This study investigates the efficacy and feasibility of dry-contact electrode materials employed in smart textiles for EMG recordings.
methodsDry-contact electrode materials were selected and implemented on textile substrates. Using these electrodes, EMG was recorded from the forearm of able-bodied subjects. 25% and 50% isometric maximum voluntary contractions were captured. A comparative investigation was performed against gel electrodes, assessing the effect of material properties on signal fidelity and strength compared.
resultsWhen isolating for electrode surface area and pressure, 31 of the 40 materials demonstrated strong positive correlations in their mean PSD with gel electrodes (r > 95,
conclusionsFor EMG dry-contact electrodes, comparing the performance against gel electrodes for the application with the selected material is important. Other factors recommended to be studied are electrodes' durability and long-term stability.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.