Evidence map›Paper›PMID 35125697›Full record

ArticleIndian journal of clinical biochemistry : IJCB2022

Analytical Method Validation for Estimation of Neurotransmitters (Biogenic Monoamines) from Cerebrospinal Fluid Using High Performance Liquid Chromatography.

Rohan V Lokhande, Ganesh R Bhagure, Alpa J Dherai, Prasad R Naik, Vrajesh P Udani, Neelu A Desai, Tester F Ashavaid

Abstract read
In one paragraph

Article in Indian journal of clinical biochemistry : IJCB, 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 3 papers.

0numbers the graph read from it
0cells of the map it votes in
3citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

3 citing papers in PubMed.

  1. Article
  2. Review
  3. Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors.

Rohan V LokhandePresent Address: Biochemistry Section, Department of Laboratory Medicine, P.D.Hinduja Hospital & MRC, Mumbai, India.
Ganesh R BhagureDepartment of Chemistry, Satish Pradhan Dnyanasadhana College, Thane, India.
Alpa J DheraiPresent Address: Biochemistry Section, Department of Laboratory Medicine, P.D.Hinduja Hospital & MRC, Mumbai, India.ORCID 0000-0002-5574-3798
Prasad R NaikPresent Address: Biochemistry Section, Department of Laboratory Medicine, P.D.Hinduja Hospital & MRC, Mumbai, India.
Vrajesh P UdaniDepartment of Paediatric Neurology, P.D.Hinduja Hospital & MRC, Mumbai, India.
Neelu A DesaiDepartment of Paediatric Neurology, P.D.Hinduja Hospital & MRC, Mumbai, India.
Tester F AshavaidPresent Address: Biochemistry Section, Department of Laboratory Medicine, P.D.Hinduja Hospital & MRC, Mumbai, India.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Biogenic amine neurotransmitters such as serotonin and dopamine are essential for signaling in both central and peripheral nervous system. Their metabolism is a multistep pathway and any defect in this results in alteration in metabolites of serotonin 5-Hydroxyindole acetic acid (5HIAA) and dopamine homovanillic acid (HVA) and 3-O-Methyl Dopa (3-OMD). Estimation of these metabolites in cerebrospinal fluid (CSF) assists in diagnosis of neurotransmitter defects. Their estimation is technically demanding and is currently available only in referral centers. We aimed to optimize a method for analysis of 5HIAA, HVA and 3-OMD. A high performance liquid chromatography (HPLC) method with electro chemical detector (ECD) was standardized for estimation. Analysis for method validation, reference range verification and clinical correlation was performed. Linearity obtained for 5-HIAA, HVA and 3-OMD was 65.35-2615.0 nmoles/l, 68.62-2745.0 nmoles/l and 236.5-4730.0 nmoles/l respectively. The coefficient of variation for internal quality controls ranged from 5 to 14% and the external proficiency testing samples (n = 16) were within peer group range. CSF metabolite levels of samples for reference range analysis overlapped with age matched ranges reported in literature. Among the 40 suspected patients analyzed for clinical testing four were found to have a neurotransmitter defect. These patients were then confirmed with molecular testing and clinical correlation. The method is validated and can be adapted in a clinical laboratory with analytical competence in HPLC.

Indexed as

Abnormal neurotransmitterBiogenic monoamineCerebrospinal fluidHPLCValidation

Identifiers

PMID35125697
PMCPMC8799795

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.