Evidence map›Paper›PMID 35117453›Full record

ArticleTranslational cancer research2020

Effects of different CT value assignment methods on dose calculations in radiotherapy planning for brain metastases.

Jianxin Ren, Guanzhong Gong, Xingmin Ma, Xinsen Yao, Yong Yin

Open access · diamondAbstract read
In one paragraph

Article in Translational cancer research, 2020. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact, top 98% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed, 0 citations in OpenAlex.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors at 2 institutions in 1 country.

Jianxin RenSchool of Physics and Technology, Wuhan University, Wuhan 430072, China.
Guanzhong GongDepartment of Radiation Oncology, Shandong Cancer Hospital and Institute, Shandong First Medical University and Shandong Academy of Medical Sciences, Jinan 250117, China.
Xingmin MaDepartment of Radiation Oncology, Shandong Cancer Hospital and Institute, Shandong First Medical University and Shandong Academy of Medical Sciences, Jinan 250117, China.
Xinsen YaoDepartment of Radiation Oncology, Shandong Cancer Hospital and Institute, Shandong First Medical University and Shandong Academy of Medical Sciences, Jinan 250117, China.
Yong YinDepartment of Radiation Oncology, Shandong Cancer Hospital and Institute, Shandong First Medical University and Shandong Academy of Medical Sciences, Jinan 250117, China.
Shandong Tumor Hospital · CNShandong First Medical University · CN

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

backgroundTo study the effects of different CT value assignment methods on the dose calculations in radiotherapy plans for brain metastases, this study will provide a reference for radiotherapy planning design based on MR images.

methodsAll fifty recruited patients underwent CT and MR simulated localization the same day as, but prior to, three dimensional conformal radiation therapy (3D-CRT) or intensity modulated radiation therapy (IMRT) for brain metastases. After rigid registration of both the CT and MR images, the main tissues and organs were delineated on the CT and MR images. The average CT value of each tissue or organ was calculated. Three groups of pseudo-CT were generated by three CT value assignment methods: (I) the whole tissue was assigned 140 HU; (II) cavity, bone and other tissues were assigned -700, 700 and 20 HU, respectively; (III) tissue- and organ-specific CT values were given. The dose distribution was recalculated based on the three groups of pseudo-CT to obtain Plan2, Plan3 and Plan4, accordingly. The resultant radiotherapy plans were considered the original plan (Plan1). Then, the dosimetric differences between these three plans and Plan1 were compared.

resultsThe average pseudo-CT values of bone and cavity were 731.7±69.3 and -725.5±26.1 HU, respectively. The range of average soft-tissue CT values was from -70 to 70 HU. The dose distribution between Plan1 and Plan2, Plan3 or Plan4 showed some differences, and the differences decreased in turn. The differences in the maximum dose of the lenses can reach 5.0%, 1.5% and 1.2%, respectively, while the differences in other dose parameters (maximum dose, mean dose and

conclusionsIn summary, a scheme for assigning specific CT values to MRI-based radiotherapy is established. The scheme will provide patients with a dose-free radiotherapy plan. Through the calculation of the differences between the new plans and the old plan, it is found that our scheme can basically control the dose error below 0.8% to meet the clinical requirements.

Indexed as

Brain metastasesCT valuesdose recalculationdosimetric comparisonpseudo-CT

Identifiers

PMID35117453
PMCPMC8798516
OpenAlexW3004685022

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC-ND
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.