ArticleTranslational cancer research2021
Effect of isocenter deviation on volume modulated arc therapy plan results and gamma passing rate in the treatment of cervical cancer.
Article in Translational cancer research, 2021. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
1 citing paper in PubMed, 2 citations in OpenAlex.
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
5 authors at 1 institution in 1 country.
Funding
No grant is acknowledged in the PubMed record.
Abstract
backgroundIsocenter deviation, often induced by small displacements of both the device and the patient, is a common error seen in radiotherapy. In this study, we investigated the impact of isocenter deviation on the results of the volumetric modulated arc therapy (VMAT) plan and dosimetric verification gamma passing rate in the treatment of cervical cancer.
methodsThe clinical data of 15 patients with cervical cancer who were treated with VMAT were retrospectively collected and analyzed. In this study, the isocenter site modification method was adopted. The VMAT plan with isocenter deviation adjustment was set as the experimental group, while the original plan was set as the control group. The impact of isocenter deviation on the results of the VMAT plan and dosimetric verification gamma passing rate was analyzed. Applying gamma analysis with different test criterions, the impact of isocenter deviation on the gamma passing rates was evaluated, and the sensitivity of different test criterions in identifying isocenter deviation was also analyzed.
resultsThere was a significant difference in the average dose in the target area between experimental group and control group (P<0.05). In organs at risk (OAR) terms, isocenter deviations also caused significant differences in dose parameters between the two groups. Except that there was no significant difference in the rectal V40 between two groups when the isocenter deviation was greater than 3 mm in the y axis direction. With the increase in the isocenter deviation, there was a trend towards decreased gamma passing rates with different analysis criterions in the experimental group. The 2 mm/2% standard had the highest sensitivity for identifying isocenter deviation.
conclusionsIsocenter deviation has significant effects on the results of the volume rotation intensity modulation plan and dosimetric verification gamma passing rates in the treatment of cervical cancer. When the isocenter deviation was less than 3 mm, a higher gamma passing rate (>90%) could also be obtained under the condition of the 3 mm/3% test criterions. It is recommended that the 2 mm/2% test standard should be utilized in clinical practice.