ArticlePloS one2022
Feasibility of dual-energy CBCT by spectral filtration of a dual-focus CNT x-ray source.
Article in PloS one, 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 3 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
3 citing papers in PubMed.
- A Dual-Energy CBCT With Reduced Scatter and Cone Beam Artifacts Using an X-Ray Source Array and Interlaced Spectral Filters.IEEE transactions on bio-medical engineering · 2026Article
- The Impact of AI on Metal Artifacts in CBCT Oral Cavity Imaging.Diagnostics (Basel, Switzerland) · 2024Article
- Low-cost dual-energy CBCT by spectral filtration of a dual focal spot X-ray source.Scientific reports · 2024Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
9 authors.
Funding
No grant is acknowledged in the PubMed record.
Abstract
Cone beam computed tomography (CBCT) is now widely used in dentistry and growing areas of medical imaging. The presence of strong metal artifacts is however a major concern of using CBCT especially in dentistry due to the presence of highly attenuating dental restorations, fixed appliances, and implants. Virtual monoenergetic images (VMIs) synthesized from dual energy CT (DECT) datasets are known to reduce metal artifacts. Although several techniques exist for DECT imaging, they in general come with significantly increased equipment cost and not available in dental clinics. The objectives of this study were to investigate the feasibility of developing a low-cost dual energy CBCT (DE-CBCT) by retrofitting a regular CBCT scanner with a carbon nanotube (CNT) x-ray source with dual focal spots and corresponding low-energy (LE) and high-energy (HE) spectral filters. A testbed with a CNT field emission x-ray source (NuRay Technology, Chang Zhou, China), a flat panel detector (Teledyne, Waterloo, Canada), and a rotating object stage was used for this feasibility study. Two distinct polychromatic x-ray spectra with the mean photon energies of 66.7keV and 86.3keV were produced at a fixed 120kVp x-ray tube voltage by using Al+Au and Al+Sn foils as the respective LE and HE filters attached to the exist window of the x-ray source. The HE filter attenuated the x-ray photons more than the LE filter. The calculated post-object air kerma rate of the HE beam was 31.7% of the LE beam. An anthropomorphic head phantom (RANDO, Nuclear Associates, Hicksville, NY) with metal beads was imaged using the testbed and the images were reconstructed using an iterative volumetric CT reconstruction algorithm. The VMIs were synthesized using an image-domain basis materials decomposition method with energy ranging from 30 to 150keV. The results were compared to the reconstructed images from a single energy clinical dental CBCT scanner (CS9300, Carestream Dental, Atlanta, GA). A significant reduction of the metal artifacts was observed in the VMI images synthesized at high energies compared to those from the same object imaged by the clinical dental CBCT scanner. The ability of the CNT x-ray source to generate the output needed to compensate the reduction of photon flux due to attenuation from the spectral filters and to maintain the CT imaging time was evaluated. The results demonstrated the feasibility of DE-CBCT imaging using the proposed approach. Metal artifact reduction was achieved in VMIs synthesized. The x-ray output needed for the proposed DE-CBCT can be generated by a fixed-anode CNT x-ray source.