Evidence map›Paper›PMID 35113282›Full record

ArticleThe international journal of cardiovascular imaging2022

Reproducibility of coronary artery calcium quantification on dual-source CT and dual-source photon-counting CT: a dynamic phantom study.

Niels R van der Werf, Ronald Booij, Marcel J W Greuter, Daniel Bos, A van der Lugt, R P J Budde, Marcel van Straten

Open access · hybridAbstract read
In one paragraph

Article in The international journal of cardiovascular imaging, 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 14 papers.

0numbers the graph read from it
0cells of the map it votes in
14citing papers in PubMed
1.7field-weighted citation impact, top 17% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

14 citing papers in PubMed, 23 citations in OpenAlex.

  1. Article
  2. Article
  3. Article
  4. Article
  5. Article
  6. Article
  7. Review
  8. Article
  9. Article
  10. Journal of medical imaging (Bellingham, Wash.) · 2023
    Article
  11. Article
  12. Article
  13. Review
  14. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors at 2 institutions in 1 country.

Niels R van der Werf *Department of Radiology & Nuclear Medicine, Erasmus University Medical Center, Rotterdam, The Netherlands. n.vanderwerf@erasmusmc.nl.ORCID http://orcid.org/0000-0003-0138-052X
Ronald Booij *Department of Radiology & Nuclear Medicine, Erasmus University Medical Center, Rotterdam, The Netherlands.
Marcel J W GreuterDepartment of Radiology, University of Groningen, University Medical Center Groningen, Groningen, The Netherlands.
Daniel BosDepartment of Radiology & Nuclear Medicine, Erasmus University Medical Center, Rotterdam, The Netherlands.
A van der LugtDepartment of Radiology & Nuclear Medicine, Erasmus University Medical Center, Rotterdam, The Netherlands.
R P J BuddeDepartment of Radiology & Nuclear Medicine, Erasmus University Medical Center, Rotterdam, The Netherlands.
Marcel van StratenDepartment of Radiology & Nuclear Medicine, Erasmus University Medical Center, Rotterdam, The Netherlands.
Erasmus MC · NLUniversity Medical Center Groningen · NL

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

To systematically compare coronary artery calcium (CAC) quantification between conventional computed tomography (CT) and photon-counting CT (PCCT) at different virtual monoenergetic (monoE) levels for different heart rates. A dynamic (heart rates of 0, < 60, 60-75, and > 75 bpm) anthropomorphic phantom with three calcification densities was scanned using routine clinical CAC protocols with CT and PCCT. In addition to the standard clinical protocol of 70 keV, PCCT images were reconstructed at monoE levels of 72, 74, and 76 keV. CAC was quantified using Agatston, volume, and mass scores. Agatston scores 95% confidence intervals (CI) were calculated and compared between PCCT and CT. Volume and mass scores were compared with physical quantities. For all CAC densities, routine clinical protocol Agatston scores of static CAC were higher for PCCT compared to CT. At < 60 bpm, Agatston scores at 74 and 76 keV reconstructions were reproducible (overlapping CI) for PCCT and CT. Increased heart rates yielded different Agatston scores for PCCT in comparison with CT, for all monoE levels. Low density CAC volume scores showed the largest deviation from physical volume, with mean deviations of 59% and 77% for CT and PCCT, respectively. Overall, mass scores underestimated physical mass by 10%, 38%, and 59% for low, medium, and high density CAC, respectively. PCCT allows for reproducible Agatston scores for dynamic CAC (< 60 bpm) when reconstructed at monoE levels of 74 or 76 keV, regardless of CAC density. Deviations from physical volume and mass were, in general, large for both CT and PCCT.

Indexed as

CalciumCoronary vesselsImaging phantomsX-ray computed tomography

Identifiers

PMID35113282
PMCPMC11142942
OpenAlexW4210762218

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.