Evidence map›Paper›PMID 35112810›Full record

ArticleAdvanced science (Weinheim, Baden-Wurttemberg, Germany)2022

Heat-Mitigated Design and Lorentz Force-Based Steering of an MRI-Driven Microcatheter toward Minimally Invasive Surgery.

Martin Francis Phelan, Mehmet Efe Tiryaki, Jelena Lazovic, Hunter Gilbert, Metin Sitti

Abstract read
In one paragraph

Article in Advanced science (Weinheim, Baden-Wurttemberg, Germany), 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 16 papers.

0numbers the graph read from it
0cells of the map it votes in
16citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

16 citing papers in PubMed.

  1. Article
  2. Article
  3. Review
  4. Smart Catheters for Diagnosis, Monitoring, and Therapy.Advanced healthcare materials · 2026
    Review
  5. Review
  6. Article
  7. Review
  8. Article
  9. Article
  10. Article
  11. Review
  12. An Approach for 3D Microprinting Soft Robotic Surgical Tools at 1.5 French Length Scales for Endovascular Interventions.IEEE International Conference on Soft Robotics. IEEE International Conference on Soft Robotics · 2024
    Article
  13. Locally Addressable Energy Efficient Actuation of Magnetic Soft Actuator Array Systems.Advanced science (Weinheim, Baden-Wurttemberg, Germany) · 2023
    Article
  14. Article
  15. Article
  16. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors.

Martin Francis PhelanPhysical Intelligence Department, Max Planck Institute for Intelligent Systems, 70569, Stuttgart, Germany.
Mehmet Efe TiryakiPhysical Intelligence Department, Max Planck Institute for Intelligent Systems, 70569, Stuttgart, Germany.
Jelena LazovicPhysical Intelligence Department, Max Planck Institute for Intelligent Systems, 70569, Stuttgart, Germany.
Hunter GilbertDepartment of Mechanical and Industrial Engineering, Louisiana State University, Baton Rouge, LA, 70803, USA.
Metin SittiPhysical Intelligence Department, Max Planck Institute for Intelligent Systems, 70569, Stuttgart, Germany.ORCID 0000-0001-8249-3854

Funding

Max Planck Society
6 · The paper itself

Abstract

Catheters integrated with microcoils for electromagnetic steering under the high, uniform magnetic field within magnetic resonance (MR) scanners (3-7 Tesla) have enabled an alternative approach for active catheter operations. Achieving larger ranges of tip motion for Lorentz force-based steering have previously been dependent on using high power coupled with active cooling, bulkier catheter designs, or introducing additional microcoil sets along the catheter. This work proposes an alternative approach using a heat-mitigated design and actuation strategy for a magnetic resonance imaging (MRI)-driven microcatheter. A quad-configuration microcoil (QCM) design is introduced, allowing miniaturization of existing MRI-driven, Lorentz force-based catheters down to 1-mm diameters with minimal power consumption (0.44 W). Heating concerns are experimentally validated using noninvasive MRI thermometry. The Cosserat model is implemented within an MR scanner and results demonstrate a desired tip range up to 110° with 4° error. The QCM is used to validate the proposed model and power-optimized steering algorithm using an MRI-compatible neurovascular phantom and ex vivo kidney tissue. The power-optimized tip orientation controller conserves as much as 25% power regardless of the catheter's initial orientation. These results demonstrate the implementation of an MRI-driven, electromagnetic catheter steering platform for minimally invasive surgical applications without the need for camera feedback or manual advancement via guidewires. The incorporation of such system in clinics using the proposed design and actuation strategy can further improve the safety and reliability of future MRI-driven active catheter operations.

Indexed as

Hot TemperatureMagnetic Resonance ImagingEquipment DesignMinimally Invasive Surgical ProceduresReproducibility of Resultsactive cathetersLorentz forcemagnetic resonance imagingmedical robotics

Identifiers

PMID35112810
PMCPMC8981448

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked