ArticleAnnals of Saudi medicine
Retrospective study of post-operative infections in implantable cardiac devices in a cardiac tertiary care center.
Article in Annals of Saudi medicine. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
2 citing papers in PubMed, 4 citations in OpenAlex.
- Preferences of Patients and Cardiologists Regarding Pacemaker Characteristics in Spain: A Discrete Choice Experiment.Patient preference and adherence · 2026Article
- Vacuum-Implemented Removal of Lead Vegetations in Cardiac Device-Related Infective Endocarditis.Journal of clinical medicine · 2022Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
5 authors at 2 institutions in 1 country.
Funding
No grant is acknowledged in the PubMed record.
Abstract
backgroundThe rise in the incidence of implantation is one of the main causes behind the increased rate of CIED infection, which is considered as a serious life-threatening complication. The need of risk factor assessment has become a necessity to prevent further complications and provide prompt management.
objectivesIdentify the risk factors of infection postoperatively among patients who have implantable cardiac devices.
designA retrospective case-control study. SETTINGS: Cardiac center for adults. PATIENTS AND
methodsThe study included all adult patients (≥14 years of age) of all nationalities who underwent cardiac electronic device implantation that was managed in the cardiac center between January 2012 to December 2018.
main outcome measuresCardiac device infection and associated risk factors. SAMPLE SIZE: 213, including 23 (10.8%) infected case patients and 190 (89.2%) non-infected controls.
resultsThe mean (SD) age of non-infected patients was 45.0 (12.7) years compared with 61.7 (13.7) for infected patients (P<.0001). Anticoagulant use, hypertension, dysplipdemia and age were the most common patient-related risk factors associated with infection. For procedural and post-procedural risk factors, the risk of infection increased as the number of leads and length of procedure increased. The device most often related to infection was the pacemaker. In the multivariate analysis, longer procedure, greater number of leads, older age, anticoagulant use, and implanted pacemaker device were independently associated with infection.
conclusionWe advise the prompt use of strict preoperative antiseptic prophylaxis measures and follow-up for post-implant patients along with patient education for early signs of infections, which will lead to improvement of both diagnosis and treatment quality for our patients in addition to reducing the economic impact on the health care system by minimizing infectious complications. LIMITATIONS: Single tertiary center study, small sample size. CONFLICT OF INTEREST: None.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials