Improvement in bladder volume reproducibility using A-mode portable ultrasound bladder scanner in moderate-hypofractionated volumetric modulated arc therapy for prostate cancer patients.

Shingo Ohira, Riho Komiyama, Naoyuki Kanayama, Kayo Sakai, Takero Hirata, Kento Yoshikata, Yoshihiro Ueda, Masayoshi Miyazaki, Masashi Nakayama, Masahiko Koizumi and 1 more

Abstract read
In one paragraph

Article in Journal of applied clinical medical physics, 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 5 papers.

0numbers the graph read from it
0cells of the map it votes in
5citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

5 citing papers in PubMed.

  1. Article
  2. Article
  3. Article
  4. Article
  5. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

11 authors.

Shingo OhiraDepartment of Radiation Oncology, Osaka International Cancer Institute, Osaka, Japan.
Riho KomiyamaDepartment of Radiation Oncology, Osaka International Cancer Institute, Osaka, Japan.
Naoyuki KanayamaDepartment of Radiation Oncology, Osaka International Cancer Institute, Osaka, Japan.
Kayo SakaiNursing Department, Osaka International Cancer Institute, Osaka, Japan.
Takero HirataDepartment of Radiation Oncology, Osaka University Graduate School of Medicine, Suita, Japan.
Kento YoshikataDepartment of Radiation Oncology, Osaka International Cancer Institute, Osaka, Japan.
Yoshihiro UedaDepartment of Radiation Oncology, Osaka International Cancer Institute, Osaka, Japan.
Masayoshi MiyazakiDepartment of Radiation Oncology, Osaka International Cancer Institute, Osaka, Japan.
Masashi NakayamaDepartment of Urology, Osaka International Cancer Institute, Osaka, Japan.
Masahiko KoizumiDepartment of Medical Physics and Engineering, Osaka University Graduate School of Medicine, Suita, Japan.
Koji KonishiDepartment of Radiation Oncology, Osaka International Cancer Institute, Osaka, Japan.

Funding

JSPS KAKENHI Grant 21K07742
6 · The paper itself

Abstract

purposeThis study introduced an A-mode portable ultrasound bladder scanner, the Lilium® α-200 (here after Lilium; Lilium Otsuka, Kanagawa, Japan), for the treatment of prostate cancer patients with hypofractionated volumetric modulated arc therapy to improve the reproducibility of bladder volume (BV). MATERIALS AND

methodsThirty patients were advised to maintain full BV prior to computed tomography (CT) simulation and daily treatment. Among these, the BV of 15 patients was measured using Lilium until a BV of 80% in the simulation was achieved (with the Lilium group). Daily cone-beam CT (CBCT) was performed for treatment. The correlation between BV measured by CBCT and Lilium was assessed. The differences in the BV and dosimetric parameters of the bladder in the CBCT versus planning CT were compared between the groups with and without Lilium.

resultsThere was a significantly strong relationship (r = 0.796, p < 0.05) between the BVs measured using CBCT and Lilium. The relative BV ratios to simulation CT < 0.5 and > 2 were observed in 10.3% and 12.7%, respectively, of treatment sessions without Lilium group, while these ratios were 1% and 2.8%, respectively, in the Lilium group. The mean absolute difference in the range of V

conclusionThe use of the A-mode portable ultrasound bladder scanner significantly improved the reproducibility of the BV, resulting in few variations in the dosimetric parameters for the bladder.

Indexed as

Prostatic NeoplasmsRadiotherapy, Intensity-ModulatedCone-Beam Computed TomographyHumansMaleRadiotherapy Planning, Computer-AssistedReproducibility of ResultsUltrasonographyUrinary Bladderbladderportable ultrasound bladder scannerprostate cancer

Identifiers

PMID35112479
PMCPMC8992960

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.