Evidence map›Paper›PMID 35112145›Full record

ArticleInternational orthopaedics2022

Biodegradable balloon spacer for massive irreparable rotator cuff tears is associated with improved functional outcomes, low revisions, and complications rate at minimum one year follow-up.

Eran Maman, Efi Kazum, Joseph A Abboud, Yarden Zinger, Shai Factor, Ofir Chechik, Oleg Dolkart

Abstract read
PubMed Publisher
In one paragraph

Article in International orthopaedics, 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 5 papers, 1 of them a synthesis that pooled it.

0numbers the graph read from it
0cells of the map it votes in
5citing papers in PubMed, 1 pooled it
2.4field-weighted citation impact, top 12% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

5 citing papers in PubMed, 1 synthesis or guideline pooled it, 12 citations in OpenAlex.

  1. Pooled it
  2. Review
  3. Review
  4. Article
  5. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors at 3 institutions in 2 countries.

Eran Maman *Division of Orthopaedic Surgery, Sackler Faculty of Medicine, Tel Aviv Sourasky Medical Center, Tel Aviv University, 6 Weizman Street, 6423906, Tel Aviv, Israel.
Efi Kazum *Division of Orthopaedic Surgery, Sackler Faculty of Medicine, Tel Aviv Sourasky Medical Center, Tel Aviv University, 6 Weizman Street, 6423906, Tel Aviv, Israel.
Joseph A AbboudDepartment of Shoulder and Elbow Surgery, Rothman Orthopaedic Institute, Philadelphia, PA, USA.
Yarden ZingerDivision of Orthopaedic Surgery, Sackler Faculty of Medicine, Tel Aviv Sourasky Medical Center, Tel Aviv University, 6 Weizman Street, 6423906, Tel Aviv, Israel.
Shai FactorDivision of Orthopaedic Surgery, Sackler Faculty of Medicine, Tel Aviv Sourasky Medical Center, Tel Aviv University, 6 Weizman Street, 6423906, Tel Aviv, Israel.
Ofir ChechikDivision of Orthopaedic Surgery, Sackler Faculty of Medicine, Tel Aviv Sourasky Medical Center, Tel Aviv University, 6 Weizman Street, 6423906, Tel Aviv, Israel.
Oleg DolkartDivision of Orthopaedic Surgery, Sackler Faculty of Medicine, Tel Aviv Sourasky Medical Center, Tel Aviv University, 6 Weizman Street, 6423906, Tel Aviv, Israel. dolkarto@gmail.com.
Tel Aviv Sourasky Medical Center · ILTel Aviv University · ILRothman Orthopaedics · US

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

purposeThis study was designed to investigate the efficacy of the InSpace balloon spacer with a specific focus on clinical and patient-related parameters, functional scores InSpace durability, and satisfaction in patients with massive irreparable rotator cuff tears (IRCT) at minimum one year follow-up.

methodsBetween 2010 and 2018, patients with symptomatic IRCTs were treated with InSpace balloon implantation. Demographic characteristics, concomitant procedures, and patient's reported outcomes (PROMs) were obtained as well as satisfaction rate and willingness to undergo the procedure again. Need for subsequent surgery and conversion to reverse total shoulder arthroplasty (RTSA) and time to conversion were also evaluated.

resultsSeventy-eight patients (mean age of 70 years, range 46-86) who underwent an InSpace (OrthoSpace, Inc., Caesarea, Israel) balloon implantation were included. Mean follow-up was 56 months (median = 49.6, range 16-129 months). Sixteen out of our 29 pseudoparalytic patients (55.2%) exceed 90° of forward flexion post-surgery with mean improvement of 73° (20-150). Patients older than 65 years of age displayed a statistically significant improved ASES score (60.6 to 46.4, P < 0.05). Patients who underwent a subscapularis (SSC) repair demonstrated a superior ASES score (63.4 compared to 50.4, P = 0.06).

conclusionsBased on the current study, spacer implantation is a low-risk, clinically effective treatment for the patients with IRCTs. Patient-specific parameters such as age, BMI, and gender should be considered during patient selection process. SSC tendon tears should be repaired if needed. Improvement in function and symptoms from this procedure may negate or delay the need for RTSA even for some of the pseudoparalytic patients.

Indexed as

Rotator Cuff InjuriesShoulder JointAgedAged, 80 and overArthroscopyFollow-Up StudiesHumansMiddle AgedRange of Motion, ArticularRetrospective StudiesRotator CuffTreatment OutcomeBiodegradable spacer balloonFunctional scoresIrreparable rotator cuff tearsPatient-related parameters