Evidence map›Paper›PMID 35111632›Full record

ArticleQuantitative imaging in medicine and surgery2022

The accuracy and reliability of 3D printed aortic templates: a comprehensive three-dimensional analysis.

Pawel Rynio, Maciej Wojtuń, Łukasz Wójcik, Miłosz Kawa, Aleksander Falkowski, Piotr Gutowski, Arkadiusz Kazimierczak

Open access · diamondAbstract read
In one paragraph

Article in Quantitative imaging in medicine and surgery, 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 8 papers.

0numbers the graph read from it
0cells of the map it votes in
8citing papers in PubMed
2.6field-weighted citation impact, top 9% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

8 citing papers in PubMed, 21 citations in OpenAlex.

  1. Article
  2. Article
  3. Article
  4. Article
  5. Article
  6. Article
  7. Article
  8. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors at 1 institution in 1 country.

Pawel RynioDepartment of Vascular Surgery, Pomeranian Medical University in Szczecin, Szczecin, Poland.
Maciej WojtuńDepartment of Radiology, Pomeranian Medical University in Szczecin, Szczecin, Poland.
Łukasz WójcikDepartment of Radiology, Pomeranian Medical University in Szczecin, Szczecin, Poland.
Miłosz KawaDepartment of Radiology, Pomeranian Medical University in Szczecin, Szczecin, Poland.
Aleksander FalkowskiDepartment of Radiology, Pomeranian Medical University in Szczecin, Szczecin, Poland.
Piotr GutowskiDepartment of Vascular Surgery, Pomeranian Medical University in Szczecin, Szczecin, Poland.
Arkadiusz KazimierczakDepartment of Vascular Surgery, Pomeranian Medical University in Szczecin, Szczecin, Poland.
Pomeranian Medical University · PL

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

backgroundAdvances in 3D printing technology allow us to continually find new medical applications. One of them is 3D printing of aortic templates to guide vascular surgeons or interventional radiologists to create fenestrations in the stent-graft surface for the implantation procedure called fenestrated endovascular aortic aneurysm repair. It is believed that the use of 3D printing significantly improves the quality of modified fenestrated stent-grafts. However, the accuracy and reliability of personalized 3D printed models of aortic templates are not well established.

methodsThirteen 3D printed templates of the visceral aorta and sixteen of the aortic arch and their corresponding computer tomography of angiography images were included in this accuracy study. The 3D models were scanned in the same conditions on computed tomography (CT) and evaluated by three physicians experienced in vascular CT assessment. Model and patient CT measurements were performed at key landmarks to maintain quality for stent-graft modification, including side branches and aortic diameters. CT-scanned aortic templates were segmented, aligned with sourced patient data, and evaluated for the Hausdorff matrix. Next, Bland-Altman plots determined the degree of agreement.

resultsThe Intraclass Correlation Coefficients values were more than 0.9 for all measurements of aortic diameters and aortic branches diameter in all landmark locations. Therefore, the reliability of the aortic templates was considered excellent. The Bland-Altman plots analysis indicated measurement biases of 0.05 to 0.47 for aortic arch templates and 0.06 to 0.38 for reno-visceral aortic templates. The arithmetic mean of Hausdorff's mean distances of the aortic arch templates was 0.47 mm (SD =0.06) and ranged from 0.34 to 0.58. The mean metrics for abdominal models was 0.24 mm (SD =0.03) and ranged from 0.21 to 0.31.

conclusionsThe printed models of 3D aortic templates are accurate and reliable, thus can be widely used in endovascular surgery and interventional radiology departments as aortic templates to guide the physician-modified fenestrated stent-graft fabrication.

Indexed as

3D printingAccuracyaneurysm modelaortic templatereliability

Identifiers

PMID35111632
PMCPMC8739108
OpenAlexW3212077544

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.