Evidence map›Paper›PMID 35109690›Full record

ArticleJournal of feline medicine and surgery2022

Cross-sectional survey of non-invasive indirect blood pressure measurement practices in cats by veterinarians.

Iliana Navarro, Stacie Summers, Mark Rishniw, Jessica Quimby

Open access · bronzeAbstract read
In one paragraph

Article in Journal of feline medicine and surgery, 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 11 papers.

0numbers the graph read from it
0cells of the map it votes in
11citing papers in PubMed
2.5field-weighted citation impact, top 12% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

11 citing papers in PubMed, 12 citations in OpenAlex.

  1. Article
  2. Review
  3. Review
  4. Review
  5. Review
  6. Article
  7. Article
  8. Article
  9. Understanding the barriers to blood pressure assessment in cats.Journal of feline medicine and surgery · 2023
    Article
  10. Under pressure: A survey of Canadian veterinarians in the diagnosis and treatment of feline hypertension.The Canadian veterinary journal = La revue veterinaire canadienne · 2023
    Article
  11. Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

4 authors at 2 institutions in 1 country.

Iliana NavarroOregon State University, Corvallis, OR, USA.
Stacie SummersOregon State University, Corvallis, OR, USA.ORCID 0000-0002-1512-9603
Mark RishniwVeterinary Information Network, Davis, CA, USA.
Jessica QuimbyThe Ohio State University, Columbus, OH, USA.ORCID 0000-0002-1388-0452
Oregon State University · USThe Ohio State University · US

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

objectivesThis survey of small animal veterinarians endeavored to: (1) determine current methods of indirect blood pressure measurement; (2) detail techniques used to reduce situational hypertension; and (3) better understand the obstacles to performing blood pressure measurement in cats.

methodsAn online survey was produced and circulated to members of the Veterinary Information Network. A total of 733 veterinarians who saw cats in their practice and had access to at least one indirect blood pressure device completed the entirety of the survey.

resultsNinety-six percent (703/733) of veterinarians who completed the survey reported measuring indirect blood pressure in cats in their practice, with veterinary technicians conducting most (600/703; 85.3%) of these measurements. Few veterinarians (30/733; 4.1%) did not measure blood pressure, with these veterinarians citing several obstacles including: difficulty interpreting results with the occurrence of fear, anxiety and stress in cats (20/30; 66.7%); difficulty performing measurements in cats (17/30; 56.7%); and technical staff being uncomfortable performing measurements (12/30; 40.0%). Most veterinarians (300/435; 69.0%) in this survey preferred an ultrasonic Doppler flow detector with sphygmomanometry, with many (272/300; 90.7%) perceiving that the results obtained with this device were more trustworthy compared with results obtained with oscillometry. Ninety percent (633/703) of veterinarians employed techniques to reduce situational hypertension in cats. Techniques perceived to be most helpful among veterinarians included: using a quiet location (454/633; 71.7%); minimizing restraint (316/633; 49.9%); performing blood pressure prior to other procedures (eg, phlebotomy, cystocentesis) (302/633; 47.7%); avoiding other animals (219/633; 34.6%); and allowing time for acclimation (167/633; 26.4%). CONCLUSIONS AND RELEVANCE: This survey study of veterinarians helps clarify obstacles to routine blood pressure measurement in conscious cats. Veterinarians reported several strategies that they felt reduced situational hypertension in cats. The data inform modifications of techniques to increase the frequency and perceived reliability of blood pressure measurement in at-risk cats.

Indexed as

Cat DiseasesHypertensionAnimalsBlood PressureCatsCross-Sectional StudiesPhlebotomyReproducibility of ResultsDopplerindirect blood pressureOscillometrysurvey

Identifiers

PMID35109690
PMCPMC10812353
OpenAlexW4210473571

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.