Evidence map›Paper›PMID 35108345›Full record

ArticlePloS one2022

Dynamic oxygenator blood volume during prolonged extracorporeal life support.

Rik H J Hendrix, Eva R Kurniawati, Sanne F C Schins, Jos G Maessen, Patrick W Weerwind

Open access · goldAbstract read
In one paragraph

Article in PloS one, 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
0.5field-weighted citation impact, top 44% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed, 6 citations in OpenAlex.

  1. Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors at 1 institution in 1 country.

Rik H J HendrixDepartment of Cardiothoracic Surgery, Maastricht University Medical Centre, Maastricht, The Netherlands.ORCID 0000-0001-6733-6287
Eva R KurniawatiDepartment of Cardiothoracic Surgery, Maastricht University Medical Centre, Maastricht, The Netherlands.ORCID 0000-0002-8637-530X
Sanne F C SchinsDepartment of Cardiothoracic Surgery, Maastricht University Medical Centre, Maastricht, The Netherlands.ORCID 0000-0002-4478-5298
Jos G MaessenDepartment of Cardiothoracic Surgery, Maastricht University Medical Centre, Maastricht, The Netherlands.
Patrick W WeerwindDepartment of Cardiothoracic Surgery, Maastricht University Medical Centre, Maastricht, The Netherlands.
Maastricht University Medical Centre · NL

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Current methods for identification of oxygenator clotting during prolonged extracorporeal life support include visual inspection, evaluation of oxygenator resistance and oxygen exchange performance, and assessment of clotting-related laboratory parameters. However, these observations do not provide a quantitative assessment of oxygenator clot formation. By measuring changes in the dynamic oxygenator blood volume this study aimed to evaluate the relation to oxygenator resistance and oxygen transfer performance. Sixty-seven oxygenators were studied during adult extracorporeal life support. Oxygenator blood volume, oxygenator resistance, and oxygen transfer efficiency were monitored. Oxygenator blood volume decreased with increasing runtime (r = -0.462; p <0.001). There was a statistically significant, fair negative correlation between oxygenator blood volume and oxygenator resistance (r = -0.476; p<0.001) in all oxygenators, which became stronger analyzing only exchanged oxygenators (r = -0.680; p<0.001) and oxygenators with an oxygenator blood volume <187 mL (r = 0.831; p<0.001). No relevant correlation between oxygenator blood volume and O2 transfer was found. Oxygenator blood volume declined over time and was clearly associated with an increasing oxygenator resistance during prolonged extracorporeal life support, though O2 transfer was less affected.

Indexed as

Blood VolumeRegional Blood FlowAdultCarbon DioxideExtracorporeal Membrane OxygenationFemaleHumansMaleMiddle AgedMonitoring, PhysiologicOxygenOxygenatorsCarbon DioxideOxygen

Identifiers

PMID35108345
PMCPMC8809600
OpenAlexW4210425489

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.