Evidence map›Paper›PMID 35106896›Full record

ArticleThe international journal of medical robotics + computer assisted surgery : MRCAS2022

Compression automation of circular stapler for preventing compression injury on gastrointestinal anastomosis.

Jin-Seok Kim, Sang-Ho Park, Nam-Su Kim, In Young Lee, Hyun Seok Jung, Hong-Min Ahn, Gyung Mo Son, Kwang-Ryul Baek

Abstract read
In one paragraph

Article in The international journal of medical robotics + computer assisted surgery : MRCAS, 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 6 papers.

0numbers the graph read from it
0cells of the map it votes in
6citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

6 citing papers in PubMed.

  1. Article
  2. Article
  3. Article
  4. Review
  5. Review
  6. Compression automation of circular stapler for preventing compression injury on gastrointestinal anastomosis.The international journal of medical robotics + computer assisted surgery : MRCAS · 2022
    Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

8 authors.

Jin-Seok KimSchool of Electronics Engineering, Pusan National University, Busan, Korea.ORCID https://orcid.org/0000-0001-5641-3339
Sang-Ho ParkSchool of Electronics Engineering, Pusan National University, Busan, Korea.
Nam-Su KimSchool of Electronics Engineering, Pusan National University, Busan, Korea.
In Young LeeDepartment of Surgery, Medical Research Institute, Pusan National University School of Medicine and Research Institute for Convergence of Biomedical Science and Technology, Pusan National University Yangsan Hospital, Yangsan, Korea.
Hyun Seok JungDepartment of Surgery, Medical Research Institute, Pusan National University School of Medicine and Research Institute for Convergence of Biomedical Science and Technology, Pusan National University Yangsan Hospital, Yangsan, Korea.
Hong-Min AhnDepartment of Surgery, Medical Research Institute, Pusan National University School of Medicine and Research Institute for Convergence of Biomedical Science and Technology, Pusan National University Yangsan Hospital, Yangsan, Korea.
Gyung Mo SonDepartment of Surgery, Medical Research Institute, Pusan National University School of Medicine and Research Institute for Convergence of Biomedical Science and Technology, Pusan National University Yangsan Hospital, Yangsan, Korea.
Kwang-Ryul BaekSchool of Electronics Engineering, Pusan National University, Busan, Korea.

Funding

Research institute for Convergence of biomedical science and technology, Pusan National University Yangsan Hospital 02-2020-008
6 · The paper itself

Abstract

backgroundConventional manual compression relies on the surgeon's subjective sensations, so excessive compression can cause tissue injury to the stapling line of the intestinal anastomosis.

methodsAutomatic compression monitoring and compression control system was developed for circular stapler. The tissue injury related compression variables were evaluated and accommodated by compression control device. The compression injury-reducing performance was verified on collagen sheets of in vitro experiments.

resultsExcessive pressure and tissue deformation were associated with compression-induced tissue damages. The safe pressure range was very narrow in weaker tissue than normal collagen. The automatic system performed proper compression within a safe pressure range without tissue injury.

conclusionsManual compression of circular stapler could cause tissue injuries by excessive pressure and tissue deformation. Our automatic compression system is designed to control peak pressure to prevent the compressive tissue injury.

Indexed as

Digestive System Surgical ProceduresSurgical StaplingAnastomosis, SurgicalAutomationHumansPressureactuatorscolorectalcomputer assisted surgerygastrointestinalminimal invasive surgeryreconstructionsensors

Identifiers

PMID35106896
PMCPMC9285555

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.