Evidence map›Paper›PMID 35106767›Full record

ArticleMedical physics2022

Technical note: Low clinical efficacy, but good acceptability of a point-of-care electronic palpation device for breast cancer screening for a lower middle-income environment.

Dustin Valdez, Teofila Cruz, Stephanie Rania, Grazyna Badowski, Kevin Cassel, Thomas Wolfgruber, Scott Grosskreutz, Louis J Dulana, Roy Adonay, Gertraud Maskarinec and 1 more

Open access · greenAbstract read
In one paragraph

Article in Medical physics, 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 3 papers, 1 of them a synthesis that pooled it.

0numbers the graph read from it
0cells of the map it votes in
3citing papers in PubMed, 1 pooled it
0.4field-weighted citation impact, top 39% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

3 citing papers in PubMed, 1 synthesis or guideline pooled it, 5 citations in OpenAlex.

  1. Pooled it
  2. Article
  3. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

11 authors at 5 institutions in 2 countries.

Dustin ValdezGraduate Program in Human Nutrition, University of Hawai'i Manoa, Honolulu, Hawaii, USA.
Teofila CruzUniversity of Guam, School of Health, Mangilao, 96923, Guam.
Stephanie RaniaHonolulu, University of Hawai'i Cancer Center, Honolulu, Hawaii, USA.
Grazyna BadowskiUniversity of Guam, School of Health, Mangilao, 96923, Guam.
Kevin CasselHonolulu, University of Hawai'i Cancer Center, Honolulu, Hawaii, USA.
Thomas WolfgruberHonolulu, University of Hawai'i Cancer Center, Honolulu, Hawaii, USA.
Scott GrosskreutzHawaii Radiologic Associates, Hilo, Hawaii, USA.
Louis J DulanaUniversity of Guam, School of Health, Mangilao, 96923, Guam.
Roy AdonayGuam Radiology Consultants, Tamuning, Guam.
Gertraud MaskarinecHonolulu, University of Hawai'i Cancer Center, Honolulu, Hawaii, USA.
John A ShepherdHonolulu, University of Hawai'i Cancer Center, Honolulu, Hawaii, USA.
University of Guam · GUCancer Center of Hawaii · USUniversity of Hawaiʻi at Mānoa · USUniversity of Hawaii System · USUniversity of Hawaii at Hilo · US

Funding

University of Guam/Cancer Research Center of Hawaii Partnership (2 of 2)U54CA143728 · NCI · UNIVERSITY OF GUAM · PI Laura Biggs · 2009 to 2026
$20.1M
University of Guam/Cancer Research Center of Hawaii Partnership (1 of 2)U54CA143727 · NCI · UNIVERSITY OF HAWAII AT MANOA · PI LYNNE R WILKENS · 2009 to 2026
$19.1M
NCI NIH HHS U54 CA143727NCI NIH HHS U54 CA143728NIH HHS NIH U54NIH HHS U54CA143727
6 · The paper itself

Abstract

backgroundLate-stage breast cancer rates in the Pacific where mammography services are limited are exceedingly high: Marshall Islands (61%), Palau (94%), and Samoa (79%). Due to the limited medical resources in these areas an alternative accessible technology is needed. The iBreast Exam (iBE) is a point-of-care electronic palpitation device that has a reported sensitivity of 86%. However, little is known about the performance and acceptability of this device for women in the Pacific.

methodsA total of 39 women (ages 42-73 years) were recruited in Guam with 19 women having a mammogram requiring biopsy (Breast Imaging-Reporting and Data System [BI-RADS] category 4 or above) and 20 women with a negative screening mammogram before the study visit. Participants received an iBE exam and completed a 26-item breast health questionnaire to evaluate the iBE. Furthermore, the performance characteristics of the iBE were tested using gelatin breast phantoms in terms of tumor size, tumor depth, and overall breast stiffness.

resultsThe iBE had a sensitivity of 20% (two true positives to eight false negatives) and specificity of 92% (24 false positives to 278 true negatives) when analyzed based on the location of the tumor by quadrant. The iBE also had generally poor agreement according to a Cohen's kappa value of 0.068. The phantom experiments showed that the iBE can detect tumors as deep as 2.5 cm, but only if the lesion is greater than 8 mm in diameter. However, the iBE did demonstrate acceptability; 67% of the women reported that they had high trust in iBE as an early detection device.

conclusionsThe iBE had generally poor sensitivity and specificity when tested in a clinical setting which does not allow its use as a screening tool. IMPACT: This study demonstrates the need for an alternative screening method other than electronic palpation for lower-middle-income areas.

Indexed as

Breast NeoplasmsAdultAgedEarly Detection of CancerElectronicsFemaleHumansMammographyMiddle AgedPalpationPoint-of-Care SystemsTreatment Outcomeaccessibilitybreastcancerpalpationscreening

Identifiers

PMID35106767
PMCPMC9007865
OpenAlexW4210609971

What OpenQuestion holds

Textmetadata
LicenceTDM
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.