ArticleJournal of ultrasound2022
Experimental evaluation of high intensity focused ultrasound for fat reduction of ex vivo porcine adipose tissue.
Article in Journal of ultrasound, 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
1 citing paper in PubMed, 3 citations in OpenAlex.
- Near-Infrared Spectral Similarity between Ex Vivo Porcine and In Vivo Human Tissue.Life (Basel, Switzerland) · 2023Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
2 authors at 1 institution in 1 country.
Funding
Abstract
purposeThe present study was stimulated by the continuous growth of commercially available high intensity focused ultrasound (HIFU) systems for fat reduction. Herein, HIFU was utilised for fat ablation using a single-element ultrasonic transducer operating in thermal mode.
methodsThe custom-made concave transducer that operates at 1.1 MHz was assessed on excised porcine adipose tissue for its ability to reduce fat. Ultrasonic sonications were executed on the adipose tissue utilising acoustical power between 14 and 75 W and sonication time in the range of 1-10 min. The mass of the adipose tissue sample was weighed afore and after ultrasonic sonications and the effect of the sonication on the mass change was recorded.
resultsMass change was linearly dependent with either increasing acoustical power or sonication time and was in the range of 0.46-1.9 g. High acoustical power of 62.5 W for a sonication time of 1 min and a power of 75 W for a sonication time of 5 min, respectively resulted in the formation of a lesion or possible cavitation on the piece of excised adipose tissue.
conclusionThe study demonstrated the efficacy of the proposed transducer in achieving a reduction of excised fat tissue. The present findings indicate the potential use of the transducer in a HIFU system indicated for the reduction of subcutaneous adipose tissue where increased values of acoustical power can result in increased amounts of fat reduction.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.