Evidence map›Paper›PMID 35104047›Full record

ArticleJournal of applied clinical medical physics2022

Development of a quasi-humanoid phantom to perform dosimetric and radiobiological measurements for out-of-field doses from external beam radiation therapy.

Marta Kruszyna-Mochalska, Agnieszka Skrobala, Piotr Romanski, Adam Ryczkowski, Wiktoria Suchorska, Katarzyna Kulcenty, Igor Piotrowski, Dorota Borowicz, Natalia Matuszak, Julian Malicki

Abstract read
In one paragraph

Article in Journal of applied clinical medical physics, 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 4 papers.

0numbers the graph read from it
0cells of the map it votes in
4citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

4 citing papers in PubMed.

  1. Article
  2. Article
  3. Article
  4. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

10 authors.

Marta Kruszyna-MochalskaElectroradiology Department, University of Medical Sciences, Poznan, Poland.
Agnieszka SkrobalaElectroradiology Department, University of Medical Sciences, Poznan, Poland.
Piotr RomanskiMedical Physics Department, Greater Poland Cancer Centre, Poznan, Poland.
Adam RyczkowskiElectroradiology Department, University of Medical Sciences, Poznan, Poland.
Wiktoria SuchorskaElectroradiology Department, University of Medical Sciences, Poznan, Poland.
Katarzyna KulcentyRadiobiology Laboratories, Medical Physics Department, Greater Poland Cancer Centre, Poznan, Poland.
Igor PiotrowskiElectroradiology Department, University of Medical Sciences, Poznan, Poland.
Dorota BorowiczMedical Physics Department, Greater Poland Cancer Centre, Poznan, Poland.
Natalia MatuszakElectroradiology Department, University of Medical Sciences, Poznan, Poland.
Julian MalickiElectroradiology Department, University of Medical Sciences, Poznan, Poland.

Funding

National Science Centre 2015/19/B/NZ7/03811
6 · The paper itself

Abstract

Our understanding of low dose, out-of-field radiation and their radiobiological effects are limited, in part due to the rapid technological advances in external beam radiotherapy, especially for non-coplanar and dynamic techniques. Reliable comparisons of out-of-field doses produced by advanced radiotherapy techniques are difficult due to the limitations of commercially available phantoms. There is a clear need for a functional phantom to accurately measure the dosimetric and radiobiological characteristics of out-of-field doses, which would in turn allow clinicians and medical physicists to optimize treatment parameters. We designed, manufactured, and tested the performance of a quasi-humanoid (Q-H) adult phantom. To test the physics parameters, we used computed tomography (CT) scans of assembled Q-H phantom. Static open field and dynamic techniques were measured both in- and out-of-field with ionization chambers and radiochromic films for two configurations (full solid and with water-filled containers). In the areas simulating soft tissues, lung, and bones, median Hounsfield units and densities were, respectively: 129.8, -738.7, 920.8 HU and 1.110, 0.215, 1.669 g/cm

Indexed as

Radiotherapy, Intensity-ModulatedAdultHumansPhantoms, ImagingRadiometryRadiotherapy DosageRadiotherapy Planning, Computer-AssistedWaterWaterhumanoid phantomsout-of-field dosesradiobiological responserisk modeling

Identifiers

PMID35104047
PMCPMC8992956

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.