Evidence map›Paper›PMID 35103386›Full record

SynthesisJournal of biomedical materials research. Part B, Applied biomaterials2022

How surface coatings on titanium implants affect keratinized tissue: A systematic review.

Casper E Van den Borre, Brandaan G R Zigterman, Maurice Y Mommaerts, Annabel Braem

Open access · hybridAbstract readSystematic Review
In one paragraph

Synthesis in Journal of biomedical materials research. Part B, Applied biomaterials, 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 16 papers, 1 of them a synthesis that pooled it.

0numbers the graph read from it
0cells of the map it votes in
16citing papers in PubMed, 1 pooled it
2.8field-weighted citation impact, top 9% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

16 citing papers in PubMed, 1 synthesis or guideline pooled it, 36 citations in OpenAlex.

  1. How surface coatings on titanium implants affect keratinized tissue: A systematic review.Journal of biomedical materials research. Part B, Applied biomaterials · 2022
    Pooled it
  2. Article
  3. Article
  4. Article
  5. Article
  6. Review
  7. Rabbit model of a biofilm-contaminated, percutaneous orthopaedic endoprosthesis.OTA international : the open access journal of orthopaedic trauma · 2025
    Review
  8. Article
  9. Article
  10. Effects of collagen modification on the osteogenic performance of different surface-modified titanium samplesHua xi kou qiang yi xue za zhi = Huaxi kouqiang yixue zazhi = West China journal of stomatology · 2024
    Article
  11. Article
  12. Effect of TiOInternational journal of dentistry · 2024
    Review
  13. Influence of Surface Characteristics of TiOMaterials (Basel, Switzerland) · 2023
    Review
  14. Article
  15. Review
  16. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

4 authors at 3 institutions in 1 country.

Casper E Van den BorreDoctoral School of Life Sciences and Medicine, Vrije Universiteit Brussel, Brussels, Belgium.
Brandaan G R ZigtermanEuropean Face Centre, Universitair Ziekenhuis Brussel, Vrije Universiteit Brussel, Brussels, Belgium.
Maurice Y MommaertsEuropean Face Centre, Universitair Ziekenhuis Brussel, Vrije Universiteit Brussel, Brussels, Belgium.
Annabel BraemDepartment of Materials Engineering, Biomaterials and Tissue Engineering Research Group, KU Leuven, Leuven, Belgium.
Universitair Ziekenhuis Brussel · BEKU Leuven · BEVrije Universiteit Brussel · BE

Funding

Internal Funds KU Leuven STG/17/024
6 · The paper itself

Abstract

Apart from osseointegration, the stability and long-term survival of percutaneous titanium implants is also strongly dependent on a qualitative soft-tissue integration in the transcutaneous region. A firm connective tissue seal is needed to minimize soft-tissue dehiscence and epithelial downgrowth. It is well-known that the implant surface plays a key role in controlling the biological response of the surrounding keratinized tissue and several coating systems have been suggested to enhance the soft-tissue cell interactions. Although some promising results have been obtained in vitro, their clinical significance can be debated. Therefore, the purpose of this systematic review is to gain more insight into the effect of such coatings on the interface formed with keratinized soft-tissue in vivo. A comprehensive search was undertaken in March 2021. Relevant electronic databases were consulted to identify appropriate studies using a set of search strings. In total, 12 out of 4971 publications were included in this review. The reported coating systems were assigned to several subgroups according to their characteristics: metallic, ceramic and composite. Notwithstanding the differences in study characteristics (animal model, implantation period, reported outcomes), it was noticed that several coatings improve the soft-tissue integration as compared to pristine titanium. Porous titanium coatings having only limited pore sizes (<250 μm) do not support dermal fibroblast tissue attachment. Yet, larger pores (>700 μm) allow extensive vascularized soft-tissue infiltration, thereby supporting cell attachment. Nanostructured ceramic coatings are found to reduce the inflammatory response in favor of the formation of cell adhesive structures, that is, hemidesmosomes. Biomolecule coatings seem of particular interest to stimulate the soft-tissue behavior provided that a durable fixation to the implant surface can be ensured. In this respect, fibroblast growth factor-2 entrapped in a biomimetic apatite coating instigates a close to natural soft-tissue attachment with epidermal collagen fibers attaching almost perpendicular to the implant surface. However, several studies had limitations with respect to coating characterization and detailed soft-tissue analysis, small sample size and short implantation periods. To date, robust and long-term in vivo studies are still lacking. Further investigation is required before a clear consensus on the optimal coating system allowing enhancing the soft-tissue seal around percutaneous titanium implants can be reached.

Indexed as

Prostheses and ImplantsTitaniumAnimalsCoated Materials, BiocompatibleOsseointegrationPorositySurface PropertiesCoated Materials, BiocompatibleTitaniumcoatingimplantkeratinized tissuesoft-tissue integrationtitaniumtranscutaneous implant

Identifiers

PMID35103386
PMCPMC9306745
OpenAlexW4210640299

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.