Evidence map›Paper›PMID 35099608›Full record

Observational studyArchives of orthopaedic and trauma surgery2023

Dual-scale single marker calibration for digital templating of total hip arthroplasty in standing radiographs: a prospective clinical study.

Christian Ries, Christoph Tobias Baltin, Stefan Haneder, Peer Eysel, Martin Hellmich, Christoph Kolja Boese

Open access · hybridFull text readObservational Study
In one paragraph

Observational study in Archives of orthopaedic and trauma surgery, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers.

0numbers the graph read from it
0cells of the map it votes in
2citing papers in PubMed
0.9field-weighted citation impact, top 29% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

2 citing papers in PubMed, 4 citations in OpenAlex.

  1. Article
  2. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors at 4 institutions in 1 country.

Christian Ries *Division of Orthopaedics, Department of Trauma and Orthopaedic Surgery, University Medical Center Hamburg-Eppendorf, Martinistr. 52, 20246, Hamburg, Germany.
Christoph Tobias Baltin *Department of Orthopaedic and Trauma Surgery, University Hospital of Cologne, Joseph-Stelzmann-Str. 24, 50931, Cologne, Germany.
Stefan HanederDepartment of Diagnostic and Interventional Radiology, University Hospital Cologne, Kerpener Str. 62, 50931, Cologne, Germany.
Peer EyselDepartment of Orthopaedic and Trauma Surgery, University Hospital of Cologne, Joseph-Stelzmann-Str. 24, 50931, Cologne, Germany.
Martin HellmichIMSB, University of Cologne, Kerpener Str. 62, 50937, Cologne, Germany.
Christoph Kolja BoeseDepartment of Orthopaedic and Trauma Surgery, University Hospital of Cologne, Joseph-Stelzmann-Str. 24, 50931, Cologne, Germany. k.boese@uke.de.
University Hospital Cologne · DEUniversität Hamburg · DEUniversity Medical Center Hamburg-Eppendorf · DEUniversity of Cologne · DE

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

purposeAccuracy of calibration of radiographs significantly influences the quality of digital templating for total hip arthroplasty (THA). The standard of care is calibration with external calibration markers (ECM). This method is associated with significant errors. Dual-scale single marker (DSSM) calibration methods may improve accuracy. The present prospective observational study is the first to analyze the application of a DSSM method in standing pelvis radiographs.

methods100 patients with unilateral THA underwent antero-posterior pelvis radiographs with ECM and DSSM. The hip components were used as reference calibration factor (internal calibration factor; ICM). Absolute differences of calibration factors for ECM and DSSM from ICM were calculated. Absolute relative deviations (ARD) were calculated. Subgroup analysis for sex and WHO BMI category was performed. Furthermore, patients reported subjective comfort for each marker using a 10-point scale and choosing the preferred marker.

resultsMaximum magnification factor differences from the ICM were 23.3% and 9.5% and mean absolute differences were 12.5% and 2.1% for the ECM and DSSM, respectively. ARD from ICM was significantly lower for DSSM compared to ECM (p < 0.001). Absolute differences increased with BMI category using ECM; calibration by DSSM was consistent in all subgroups. Patients preferred DSSM over ECM (n = 53) or were indifferent (n = 20). Comfort was rated significantly higher for DSSM versus ECM (p < 0.001).

conclusionDSSM method showed superior results in comparison to the ECM method for calibration of digital radiographs. DSSM could be used to improve digital templating in standing radiographs.

Indexed as

Arthroplasty, Replacement, HipCalibrationHip JointHumansProspective StudiesRadiographyDigital radiographyDigital templatingHip arthroplastyHip replacement

Identifiers

PMID35099608
PMCPMC10030446
OpenAlexW4210362861

What OpenQuestion holds

Textfull text, public
LicenceCC BY
measurements read15
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.