Evidence map›Paper›PMID 35098767›Full record

ArticleInterventional neuroradiology : journal of peritherapeutic neuroradiology, surgical procedures and related neurosciences2022

Long-term efficacy and safety of WovenEndoBridge (WEB)-assisted cerebral aneurysm embolization.

Oktay Algin, Seniha Corabay, Gıyas Ayberk

Abstract read
In one paragraph

Article in Interventional neuroradiology : journal of peritherapeutic neuroradiology, surgical procedures and related neurosciences, 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 12 papers, 2 of them syntheses that pooled it.

0numbers the graph read from it
0cells of the map it votes in
12citing papers in PubMed, 2 pooled it
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

12 citing papers in PubMed, 2 syntheses or guidelines pooled it.

  1. Long-term outcomes of the Woven EndoBridge device for treatment of intracranial aneurysms: A systematic review and meta-analysis.Interventional neuroradiology : journal of peritherapeutic neuroradiology, surgical procedures and related neurosciences · 2026
    Pooled it
  2. Pooled it
  3. Article
  4. Woven EndoBridge versus stent-assisted coil embolization for the treatment of ruptured wide-necked aneurysms: A multicentric experience.Interventional neuroradiology : journal of peritherapeutic neuroradiology, surgical procedures and related neurosciences · 2026
    Article
  5. Quantitative radial force measurements of Woven EndoBridge devices.Interventional neuroradiology : journal of peritherapeutic neuroradiology, surgical procedures and related neurosciences · 2026
    Article
  6. Article
  7. Article
  8. Article
  9. Article
  10. Article
  11. Article
  12. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

3 authors.

Oktay AlginDepartment of Radiology, 3129City Hospital, Ankara, Turkey.ORCID 0000-0002-3877-8366
Seniha CorabayBiostatistics Department, 37523Uludag University, Bursa, Turkey.
Gıyas AyberkDepartment of Neurosurgery, Yildirim Beyazit University, Ankara, Turkey.ORCID 0000-0002-9258-4001

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

purposeLong-term compaction, compression, migration, and recurrence rates of the WovenEndoBridge devices remain unknown. The purpose of this study was to detect these rates and safety profiles of the WovenEndoBridge within 7 years period. MATERIALS AND

methodsEighty-three aneurysms of 79 patients treated with the WovenEndoBridge device were retrospectively evaluated using an occlusion scale (e.g. complete occlusion, neck remnant, and aneurysm remnant) on angiography images.

resultsThe residual aneurysm was observed in 11 (13%) aneurysms. The mean and median diameters of the recurrent aneurysms were 6 and 7 mm. Most of the recurrent aneurysms were complex type and/or ruptured. Mean diameters and the neck-to-body ratios of all residual aneurysms in the preoperative imaging exams were above 4 mm and 0.6, respectively. The median values of preoperative height and neck measurements were higher in the recurrent aneurysms than in the adequate occlusion group ( DISCUSSION: Our adequate occlusion rate was 87%. Occlusion rates are less favorable than aneurysms with a long height, wide neck, or high neck-to-body ratio. Our study confirms the high safety and efficiency of the WovenEndoBridge. Compaction, compression, and/or migration of the WovenEndoBridge and the presence of intra-aneurysmal thrombosis are the main reasons for the recurrences.

Indexed as

Embolization, TherapeuticEndovascular ProceduresIntracranial AneurysmCerebral AngiographyDisease ProgressionHumansRetrospective StudiesTreatment OutcomeCerebral aneurysmembolizationintrasaccular flow diverterrecurrenceWoven EndoBridge

Identifiers

PMID35098767
PMCPMC9706260

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.