ArticleInterventional neuroradiology : journal of peritherapeutic neuroradiology, surgical procedures and related neurosciences2022
Long-term efficacy and safety of WovenEndoBridge (WEB)-assisted cerebral aneurysm embolization.
Article in Interventional neuroradiology : journal of peritherapeutic neuroradiology, surgical procedures and related neurosciences, 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 12 papers, 2 of them syntheses that pooled it.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
12 citing papers in PubMed, 2 syntheses or guidelines pooled it.
- Long-term outcomes of the Woven EndoBridge device for treatment of intracranial aneurysms: A systematic review and meta-analysis.Interventional neuroradiology : journal of peritherapeutic neuroradiology, surgical procedures and related neurosciences · 2026Pooled it
- Use of the Woven EndoBridge Device for Sidewall Aneurysms: Systematic Review and Meta-analysis.AJNR. American journal of neuroradiology · 2023Pooled it
- Early Aneurysm Occlusion Outcomes After Endovascular Treatment: A Descriptive Single-Center Cohort Evaluation.Neurology international · 2026Article
- Woven EndoBridge versus stent-assisted coil embolization for the treatment of ruptured wide-necked aneurysms: A multicentric experience.Interventional neuroradiology : journal of peritherapeutic neuroradiology, surgical procedures and related neurosciences · 2026Article
- Quantitative radial force measurements of Woven EndoBridge devices.Interventional neuroradiology : journal of peritherapeutic neuroradiology, surgical procedures and related neurosciences · 2026Article
- Optimal woven endobridge (WEB) device-aneurysm volume: using automated volumetric software to predict aneurysmal occlusion status after WEB treatment.Acta neurochirurgica · 2025Article
- The Use of Macrocyclic Contrast Agents and Woven EndoBridge-Assisted Embolization for Direct Carotid-Cavernous Fistulas due to Aneurysm Rupture.Neurointervention · 2025Article
- Design of thermally programmable 3D shape memory polymer-based devices tailored for endovascular treatment of intracranial aneurysms.Journal of the mechanical behavior of biomedical materials · 2024Article
- Comparison of Angiographic Outcomes of Woven EndoBridge and Balloon-Assisted Coiling for the Treatment of Ruptured Wide-Necked Aneurysms: A Multicentric Study.Stroke (Hoboken, N.J.) · 2024Article
- Intrasaccular Flow Disruptor (Woven EndoBridge) Assisted Embolization of Vertebral Arteriovenous Fistulas.Neurointervention · 2024Article
- Microsurgical clipping as a retreatment strategy for previously ruptured aneurysms treated with the Woven EndoBridge (WEB) device: a mono-institutional case series.Acta neurochirurgica · 2023Article
- Woven EndoBridge in Wide-Neck Bifurcation Aneurysms: Digital Subtraction Angiography at 3-Year Follow-Up.Journal of clinical medicine · 2022Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
3 authors.
Funding
No grant is acknowledged in the PubMed record.
Abstract
purposeLong-term compaction, compression, migration, and recurrence rates of the WovenEndoBridge devices remain unknown. The purpose of this study was to detect these rates and safety profiles of the WovenEndoBridge within 7 years period. MATERIALS AND
methodsEighty-three aneurysms of 79 patients treated with the WovenEndoBridge device were retrospectively evaluated using an occlusion scale (e.g. complete occlusion, neck remnant, and aneurysm remnant) on angiography images.
resultsThe residual aneurysm was observed in 11 (13%) aneurysms. The mean and median diameters of the recurrent aneurysms were 6 and 7 mm. Most of the recurrent aneurysms were complex type and/or ruptured. Mean diameters and the neck-to-body ratios of all residual aneurysms in the preoperative imaging exams were above 4 mm and 0.6, respectively. The median values of preoperative height and neck measurements were higher in the recurrent aneurysms than in the adequate occlusion group ( DISCUSSION: Our adequate occlusion rate was 87%. Occlusion rates are less favorable than aneurysms with a long height, wide neck, or high neck-to-body ratio. Our study confirms the high safety and efficiency of the WovenEndoBridge. Compaction, compression, and/or migration of the WovenEndoBridge and the presence of intra-aneurysmal thrombosis are the main reasons for the recurrences.