Evidence map›Paper›PMID 35096562›Full record

ArticleFrontiers in oncology2021

Self-Expandable Metallic Stent Implantation Combined With Bronchial Artery Infusion Chemoembolization in the Treatment of Lung Cancer With Complete Atelectasis.

Xiaobing Li, Meipan Yin, Pengfei Xie, Ying Liu, Xiangnan Li, Yu Qi, Yaozhen Ma, Chunxia Li, Gang Wu

Open access · goldAbstract read
In one paragraph

Article in Frontiers in oncology, 2021. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 3 papers.

0numbers the graph read from it
0cells of the map it votes in
3citing papers in PubMed
0.2field-weighted citation impact, top 55% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

3 citing papers in PubMed, 1 citations in OpenAlex.

  1. Article
  2. Article
  3. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

9 authors at 1 institution in 1 country.

Xiaobing LiDepartment of Interventional Radiology, The First Affiliated Hospital of Zhengzhou University, Zhengzhou, China.
Meipan YinDepartment of Interventional Radiology, The First Affiliated Hospital of Zhengzhou University, Zhengzhou, China.
Pengfei XieDepartment of Interventional Radiology, The First Affiliated Hospital of Zhengzhou University, Zhengzhou, China.
Ying LiuDepartment of Respiratory, The First Affiliated Hospital of Zhengzhou University, Zhengzhou, China.
Xiangnan LiDepartment of Thoracic Surgery, The First Affiliated Hospital of Zhengzhou University, Zhengzhou, China.
Yu QiDepartment of Thoracic Surgery, The First Affiliated Hospital of Zhengzhou University, Zhengzhou, China.
Yaozhen MaDepartment of Interventional Radiology, The First Affiliated Hospital of Zhengzhou University, Zhengzhou, China.
Chunxia LiDepartment of Interventional Radiology, The First Affiliated Hospital of Zhengzhou University, Zhengzhou, China.
Gang WuDepartment of Interventional Radiology, The First Affiliated Hospital of Zhengzhou University, Zhengzhou, China.
First Affiliated Hospital of Zhengzhou University · CN

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

backgroundAtelectasis is a common complication of lung cancer, and there are few reports about the treatment methods. This study retrospectively analyzed the safety and effectiveness of endotracheal metal stent implantation combined with arterial infusion chemoembolization in the treatment of non-small cell lung cancer with complete atelectasis.

methodsThe clinical data of patients with non-small cell lung cancer and complete atelectasis treated by self-expandable metallic stent implantation combined with arterial infusion chemotherapy were retrospectively analyzed. The clinical efficacy was evaluated and postoperative adverse reactions were observed. Progression-free survival and overall survival were analyzed by Kaplan-Meier method.

resultsIn all, 42 endotracheal metallic stents were implanted in 42 patients under fluoroscopy. 5-7 days after stent implantation, CT showed that 24 patients (57.1%) had complete lung recruitment, and that 13 (31.0%) had partial lung recruitment. The technical success rate was 100%, and the clinical success rate was 88.1% (37/42). 5-7 days after stent implantation, bronchial artery infusion chemoembolization was performed in all patients. The median progression-free survival and overall survival were 6 months (95% CI: 2.04-9.66) and 10 months (95% CI: 7.22-12.79), respectively.

conclusionSelf-expandable metallic stent implantation combined with arterial infusion chemoembolization may be an effective and safe strategy in the treatment of lung cancer with atelectasis clinically.

Indexed as

atelectasisbronchial artery infusion chemoembolizationinterventional radiologylung cancerself-expandable metallic stent

Identifiers

PMID35096562
PMCPMC8790529
OpenAlexW4206544603

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked