Evidence map›Paper›PMID 35093124›Full record

ArticleJournal of orthopaedic surgery and research2022

Accuracy and reliability of tridimensional electromagnetic sensor system for elbow ROM measurement.

Kohei Yamaura, Yutaka Mifune, Atsuyuki Inui, Hanako Nishimoto, Takeshi Kataoka, Takashi Kurosawa, Shintaro Mukohara, Yuichi Hoshino, Takahiro Niikura, Kouki Nagamune and 1 more

Abstract read
In one paragraph

Article in Journal of orthopaedic surgery and research, 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers.

0numbers the graph read from it
0cells of the map it votes in
2citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

2 citing papers in PubMed.

  1. Article
  2. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

11 authors.

Kohei YamauraDepartment of Orthopaedic Surgery, Kobe University Graduate School of Medicine, 7-5-2, Kusunoki-cho, Chuo-ku, Kobe, 650-0017, Japan.
Yutaka MifuneDepartment of Orthopaedic Surgery, Kobe University Graduate School of Medicine, 7-5-2, Kusunoki-cho, Chuo-ku, Kobe, 650-0017, Japan. m-ship@kf7.so-net.ne.jp.ORCID http://orcid.org/0000-0002-9612-5785
Atsuyuki InuiDepartment of Orthopaedic Surgery, Kobe University Graduate School of Medicine, 7-5-2, Kusunoki-cho, Chuo-ku, Kobe, 650-0017, Japan.
Hanako NishimotoDepartment of Orthopaedic Surgery, Kobe University Graduate School of Medicine, 7-5-2, Kusunoki-cho, Chuo-ku, Kobe, 650-0017, Japan.
Takeshi KataokaDepartment of Orthopaedic Surgery, Kobe University Graduate School of Medicine, 7-5-2, Kusunoki-cho, Chuo-ku, Kobe, 650-0017, Japan.
Takashi KurosawaDepartment of Orthopaedic Surgery, Kobe University Graduate School of Medicine, 7-5-2, Kusunoki-cho, Chuo-ku, Kobe, 650-0017, Japan.
Shintaro MukoharaDepartment of Orthopaedic Surgery, Kobe University Graduate School of Medicine, 7-5-2, Kusunoki-cho, Chuo-ku, Kobe, 650-0017, Japan.
Yuichi HoshinoDepartment of Orthopaedic Surgery, Kobe University Graduate School of Medicine, 7-5-2, Kusunoki-cho, Chuo-ku, Kobe, 650-0017, Japan.
Takahiro NiikuraDepartment of Orthopaedic Surgery, Kobe University Graduate School of Medicine, 7-5-2, Kusunoki-cho, Chuo-ku, Kobe, 650-0017, Japan.
Kouki NagamuneHuman and Artificial Intelligent Systems, University of Fukui Graduate School of Engineering, Fukui, Japan.
Ryosuke KurodaDepartment of Orthopaedic Surgery, Kobe University Graduate School of Medicine, 7-5-2, Kusunoki-cho, Chuo-ku, Kobe, 650-0017, Japan.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

backgroundWhile the precise measurement of the range of motion (ROM) of the elbow joint is important for clinical assessment and rehabilitation, problems include low accuracy and reproducibility in goniometer measurements due to the influence of soft tissue. The purpose of this study was to validate elbow joint motion analysis using a three-dimensional electromagnetic sensor system (EMS).

methodsThe accuracy and reproducibility of the EMS system were evaluated at four angles (0°, 45°, 90°, and 135°) using a model bone of the humerus and forearm. In addition, the maximum extension and maximum flexion of six elbows of six healthy volunteers were assessed by radiographic and EMS measurements. Accuracy was assessed by calculating the mean value of the measurement angle, standard deviation, Pearson's correlation coefficient, and the Bland-Altman method. Reproducibility was assessed by calculating the intra-rater and inter-rater reliabilities using intraclass correlation coefficients.

resultsIn the model bone evaluation, the mean angles of the EMS measurement were 1.2° ± 2.0°, 45.4° ± 2.1°, 91.7° ± 2.4°, and 134.6° ± 2.7° at 0°, 45°, 90°, and 135°, respectively. In the in vivo evaluation, the elbow angles at the maximum extension with the EMS and radiographic angles were 4.7° ± 3.0° and 2.7° ± 2.0°, respectively, and the angles at maximum flexion were 131.8° ± 13.0° and 130.8° ± 4.5°, respectively. There were statistically significant correlations between the EMS and radiographic measurements; the Bland-Altman plots indicated that the two methods were almost in agreement for both extension and flexion.

conclusionsThis method of measuring ROM of the elbow joint using EMS showed high accuracy, reliability, and reproducibility. The current results demonstrated the possibility of using the electromagnetic system to provide an accurate evaluation of the elbow joint in clinical settings.

Indexed as

Range of Motion, ArticularBiosensing TechniquesElbowElbow JointElectromagnetic PhenomenaHumansImaging, Three-DimensionalReproducibility of ResultsElbow jointElectromagnetic sensor systemRange of motion

Identifiers

PMID35093124
PMCPMC8800242

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.