Evidence map›Paper›PMID 35093022›Full record

ArticleBMC gastroenterology2022

The impact of face shields on the quality of gastrointestinal endoscopy during the COVID-19 pandemic.

Jong Yoon Lee, Yeo Wool Kang, Myeongseok Koh, Dong Kyun Kim, Jin Seok Jang, Jong Hoon Lee

Open access · goldAbstract read
In one paragraph

Article in BMC gastroenterology, 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers.

0numbers the graph read from it
0cells of the map it votes in
2citing papers in PubMed
0.2field-weighted citation impact, top 49% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

2 citing papers in PubMed, 2 citations in OpenAlex.

  1. Article
  2. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors at 1 institution in 1 country.

Jong Yoon LeeDepartment of Internal Medicine, Dong-A University College of Medicine, Busan, 49201, South Korea.
Yeo Wool KangDepartment of Internal Medicine, Dong-A University College of Medicine, Busan, 49201, South Korea.
Myeongseok KohDepartment of Internal Medicine, Dong-A University College of Medicine, Busan, 49201, South Korea.
Dong Kyun KimDepartment of Internal Medicine, Dong-A University College of Medicine, Busan, 49201, South Korea.
Jin Seok JangDepartment of Internal Medicine, Dong-A University College of Medicine, Busan, 49201, South Korea.
Jong Hoon LeeDepartment of Internal Medicine, Dong-A University College of Medicine, Busan, 49201, South Korea. leejonghoon2002@gmail.com.
Dong-A University · KR

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

backgroundCoronavirus disease 2019 (COVID-19) has become a global pandemic, with healthcare workers at a high risk of exposure. During this pandemic, endoscopists must wear personal protective equipment (PPE), including face shields, to prevent COVID-19 transmission; however, few studies have reported the impact of face shields on the quality of gastrointestinal (GI) endoscopy. We aimed to determine whether the use of PPE, including face shields, affected the quality of GI endoscopy during the COVID-19 pandemic.

methodsThe medical records of patients who had undergone screening or surveillance colonoscopy and gastric endoscopic submucosal dissection (ESD) at Dong-A University Hospital between June 2020 and March 2021 were retrospectively reviewed. Endoscopists wore isolation gowns, disposable gloves, and KF94 masks from June 2020 to October 2020. From November 2020, endoscopists also wore face shields. We compared GI endoscopy quality indicators between the first five months (no face shields) and the second five months (with face shields). In the non-face shield and face shield groups, we calculated the overall adenoma detection rates (ADRs), polyp detection rate (PDR), sessile serrated lesion detection rate (SSLDR), advanced neoplasia detection rate (ANDR), complete resection rate (CRR), number of polyps and/or adenomas per colonoscopy, and gastric ESD procedure time.

resultsIn total, 1359 study patients had undergone screening or surveillance colonoscopy (face shield group, n = 679; non-face shield group, n = 680). No statistically significant between-group differences were observed (PDR, 49.04 vs. 52.50%, p = 0.202; ADR, 38.59 vs. 38.97%, p = 0.884; SSPDR, 1.91 vs. 1.32%, p = 0.388; ANDR, 3.98 vs. 3.97%, p = 0.991, respectively). No difference was found in colonoscopy quality indicators between patients examined by experienced and trainee endoscopists with and without face shields. Of 144 study patients who had undergone gastric ESD for gastric neoplasms, there were 72 patients in each group. No statistically significant differences were found in the CRR (94.44 vs 93.05%, p = 1.000) and procedure times (19.22 ± 9.33 vs. 19.03 ± 11.49, p = 0.911).

conclusionsWearing face shields during the COVID-19 pandemic did not affect the quality indicators for GI endoscopy.

Indexed as

COVID-19ColonoscopyHumansPandemicsRetrospective StudiesSARS-CoV-2Adenomatous polypsColonic polypsColonoscopyCOVID-19Endoscopy

Identifiers

PMID35093022
PMCPMC8800408
OpenAlexW4210369278

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.