Evidence map›Paper›PMID 35092393›Full record

ArticleAsian Pacific journal of cancer prevention : APJCP2022

Are All Views with and without Displacement Maneuver Necessary in Augmentation Mammography? Putting Numbers Into Perspective.

Lilian Soares Couto, Ruffo Freitas-Junior, Rosangela Silveira Corrêa, Macelo Vilela Lauar, Selma Pace Bauab, Linei Augusta Brolini Dellê Urban, Jorge Luiz Oliveira Cruvinel-Filho, Leonardo Ribeiro Soares, Ricardo Francalacci Savaris

Abstract readComparative Study
In one paragraph

Article in Asian Pacific journal of cancer prevention : APJCP, 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 4 papers.

0numbers the graph read from it
0cells of the map it votes in
4citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

4 citing papers in PubMed.

  1. Article
  2. Article
  3. Article
  4. Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

9 authors.

Lilian Soares CoutoMastology Program, Hospital das Clínicas of UFG, 1ª Avenida, s/nº, Setor Universitário. Goiânia, Goiás. ZIP: 74.605-050. Brazil.ORCID 0000-0001-7557-0751
Ruffo Freitas-JuniorMastology Program, Hospital das Clínicas of UFG, 1ª Avenida, s/nº, Setor Universitário. Goiânia, Goiás. ZIP: 74.605-050. Brazil.ORCID 0000-0003-4145-8598
Rosangela Silveira CorrêaMastology Program, Hospital das Clínicas of UFG, 1ª Avenida, s/nº, Setor Universitário. Goiânia, Goiás. ZIP: 74.605-050. Brazil.ORCID 0000-0002-1681-168X
Macelo Vilela LauarMastology Program, Hospital das Clínicas of UFG, 1ª Avenida, s/nº, Setor Universitário. Goiânia, Goiás. ZIP: 74.605-050. Brazil.ORCID 0000-0001-6314-0797
Selma Pace BauabMastology Program, Hospital das Clínicas of UFG, 1ª Avenida, s/nº, Setor Universitário. Goiânia, Goiás. ZIP: 74.605-050. Brazil.ORCID 0000-0002-1296-2165
Linei Augusta Brolini Dellê UrbanMastology Program, Hospital das Clínicas of UFG, 1ª Avenida, s/nº, Setor Universitário. Goiânia, Goiás. ZIP: 74.605-050. Brazil.ORCID 0000-0003-2017-9776
Jorge Luiz Oliveira Cruvinel-FilhoMastology Program, Hospital das Clínicas of UFG, 1ª Avenida, s/nº, Setor Universitário. Goiânia, Goiás. ZIP: 74.605-050. Brazil.ORCID 0000-0002-7809-3994
Leonardo Ribeiro SoaresMastology Program, Hospital das Clínicas of UFG, 1ª Avenida, s/nº, Setor Universitário. Goiânia, Goiás. ZIP: 74.605-050. Brazil.ORCID 0000-0002-9448-6114
Ricardo Francalacci SavarisMastology Program, Hospital das Clínicas of UFG, 1ª Avenida, s/nº, Setor Universitário. Goiânia, Goiás. ZIP: 74.605-050. Brazil.ORCID 0000-0002-2779-5443

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

objectiveAugmentation implants pose a challenge for radiologists. Displacing the implant allows slightly more breast tissue to be visualized than the standard compression views. The objective of this study was to verify the agreement between craniocaudal (CC) views and CC with implant displacement (CC-ID), mediolateral oblique (MLO) and MLO-ID and the inter- and intraobserver agreement of mammographic images for finding abnormal images.

methodsThe main outcomes [BI-RADS® normal=1,2; abnormal=3,4,5)] were analysed by 3 readers (reader1; reader 2, 1st round, reader 2, 2nd round) in 360 women with breast implants. Comparison between CC/CC-ID and MLO/MLO-ID, and degree of agreement for mammographic images between researchers were made using Kappa index. Proportions were calculated using a 95% confidence interval (95%CI).

resultsA total of 87 abnormal findings were identified by reader 2, 2nd round. Abnormal findings were observed in CC-ID=18.8% (68 out of 360; 95%CI=15.1%-23.2%) compared to CC=10.8% (39 out of 360; 95%CI=8%-14.4%, k=0.49); in MLO=10.5% (38 out of 360; 95%CI=7.7%-14.1%) compared to MLO-ID=15.8% (57 out of 360; 95%CI=12.4%-19.9%, k=0.55). The CC-ID was the view that singly identified more abnormal findings (20 out of 87; 23%; 95%CI=15.4% to 32.8%) and the CC was the view that least detected abnormal findings (1 out 87; 95%CI=0.2% to 6.2%). The inter- and intraobserver agreement between readers views was 0.67 and 0.74 respectively.

conclusionsIn women with breast augmentation implants, all views are necessary to identify breast tissue abnormalities. In our sample, the inter- and intraobserver agreement were "substantial".

Indexed as

Breast ImplantsAdultBreastBreast DiseasesCross-Sectional StudiesFemaleHumansMammographyObserver VariationReproducibility of ResultsRetrospective StudiesBreastBreast augmentationbreast cancerBreast Implantsmammography

Identifiers

PMID35092393
PMCPMC9258642

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.