ArticleMagnetic resonance in medicine2022
Plug-and-play advanced magnetic resonance spectroscopy.
Article in Magnetic resonance in medicine, 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 16 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
16 citing papers in PubMed.
- Short Echo-Time Spiral MRSI Versus Single-Voxel Spectroscopy in the Human Brain at 3 Tesla With Semi-LASER Localization.Magnetic resonance in medicine · 2026Article
- Does sex moderate health and Alzheimer's disease risk tied to early educational experiences? The reducing inequities through social and educational change follow-up in early adulthood extension study protocol.Brain, behavior, & immunity - health · 2026Article
- Value of MRI Outcomes for Preventive and Early-Stage Trials in Spinocerebellar Ataxias 1 and 3.Annals of clinical and translational neurology · 2026Article
- MRS4Brain: a software for preclinical proton and deuterium-based MR spectroscopic imaging data.Magma (New York, N.Y.) · 2026Article
- Neurochemical Endpoints to Inform Early-Stage Trials of Spinocerebellar Ataxia 2 and 3 in a Multisite Setting.Annals of clinical and translational neurology · 2026Article
- Development and in vivo proof-of-concept of delayed alternating nutation tailored excitation point resolved spectroscopy (dante-press): a frequency-selective single voxel spectroscopy sequence applied to in vivo measurements of naa and glu at 7.0 T.Magma (New York, N.Y.) · 2026Article
- Introducing the SAGE study: a multimodal protocol for testing a GABAergic mechanism of age-related episodic memory impairment across the sexes.BMJ neurology open · 2026Article
- Myo-Inositol Deficiency, Structural Brain Changes, and Cerebral Perfusion Alterations in Classic Galactosemia: Preliminary Insights From a Multiparametric MRI Study.Journal of inherited metabolic disease · 2025Article
- Neurochemical Profiles of Prefrontal Cortex and Hypothalamus at 3 and 7 T During Controlled Euglycemia: Evaluation in a Cohort With Type 1 Diabetes.NMR in biomedicine · 2025Article
- MRI Voxel Morphometry Shows Brain Volume Changes in Breast Cancer Survivors: Implications for Treatment.Pathophysiology : the official journal of the International Society for Pathophysiology · 2025Article
- Sensitivity of Advanced Magnetic Resonance Imaging to Progression over Six Months in Early Spinocerebellar Ataxia.Movement disorders : official journal of the Movement Disorder Society · 2024Article
- MR Imaging in Ataxias: Consensus Recommendations by the Ataxia Global Initiative Working Group on MRI Biomarkers.Cerebellum (London, England) · 2024Review
- Fast high-resolution prospective motion correction for single-voxel spectroscopy.Magnetic resonance in medicine · 2024Article
- Neuroimaging to Facilitate Clinical Trials in Huntington's Disease: Current Opinion from the EHDN Imaging Working Group.Journal of Huntington's disease · 2024Review
- Clinically Meaningful Magnetic Resonance Endpoints Sensitive to Preataxic Spinocerebellar Ataxia Types 1 and 3.Annals of neurology · 2023Article
- Quantitative MR Markers in Non-Myelopathic Spinal Cord Compression: A Narrative Review.Journal of clinical medicine · 2022Review
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
9 authors.
Funding
Abstract
purposeAdvanced MRS protocols improve data quality and reproducibility relative to vendor-provided protocols; however, they are challenging to incorporate into the clinical workflow and require local MRS expertise for successful implementation. Here, we developed an automated advanced MRS acquisition protocol at 3T to facilitate acquisition of high-quality spectroscopic data without local MRS expertise.
methodsFirst, a B
resultsA multi-iteration FAST(EST)MAP protocol resulted in narrower water linewidths than vendor's B
conclusionThe plug-and-play advanced MRS protocol allows automated acquisition of high-quality MRS data with high success rate and consistency on a clinical 3T platform.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.