Evidence map›Paper›PMID 35089857›Full record

ArticleIEEE transactions on medical imaging2022

High-Speed Balanced-Detection Visible-Light Optical Coherence Tomography in the Human Retina Using Subpixel Spectrometer Calibration.

Ian Rubinoff, David A Miller, Roman Kuranov, Yuanbo Wang, Raymond Fang, Nicholas J Volpe, Hao F Zhang

Abstract read
In one paragraph

Article in IEEE transactions on medical imaging, 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 23 papers.

0numbers the graph read from it
0cells of the map it votes in
23citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

23 citing papers in PubMed.

  1. Article
  2. Article
  3. Article
  4. Article
  5. Article
  6. Article
  7. Spectroscopic analysis of volumetric OCT data for the automated measurement of scatterer size.Journal of the Optical Society of America. A, Optics, image science, and vision · 2025
    Article
  8. Article
  9. Review
  10. Article
  11. Article
  12. Review
  13. Article
  14. Review
  15. Article
  16. Review
  17. bioRxiv : the preprint server for biology · 2024
    Article
  18. Article
  19. Article
  20. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors.

Ian Rubinoff
David A Miller
Roman Kuranov
Yuanbo Wang
Raymond Fang
Nicholas J Volpe
Hao F Zhang

Funding

Novel Glaucoma Diagnostics for Structure and Function - Renewal - 1R01EY013178 · NEI · WILLS EYE HEALTH SYSTEM · PI Joel S Schuman · 2000 to 2026
$17.5M
ER Stress and Diabetic RetinopathyR01EY019949 · NEI · UNIVERSITY OF OKLAHOMA HLTH SCIENCES CTR · PI ZHANG, SARAH X · 2010 to 2023
$5.5M
Clinical glaucoma management enabled by visible-light OCTU01EY033001 · NEI · NORTHWESTERN UNIVERSITY · PI SCHUMAN, JOEL S, ZHANG, HAO F · 2021 to 2025
$3.2M
Visible-light optical coherence tomography for clinical glaucoma managementR44EY026466 · NEI · OPTICENT, INC. · PI KURANOV, ROMAN · 2018 to 2023
$2.7M
Investigating oxygen metabolism in diabetic retinopathyR01EY026078 · NEI · NORTHWESTERN UNIVERSITY · PI SHEIBANI, NADER, ZHANG, HAO F · 2016 to 2020
$2.3M
Investigating nanoscale neuronal damages in early glaucoma towards clinical optical detectionR01EY029121 · NEI · NORTHWESTERN UNIVERSITY · PI LIU, XIAORONG, ZHANG, HAO F · 2018 to 2021
$2.0M
Mechanisms underlying the formation of the cornea and ocular surface epitheliumR01EY028304 · NEI · NORTHWESTERN UNIVERSITY AT CHICAGO · PI KUME, TSUTOMU · 2018 to 2021
$1.6M
Visual Sciences T32T32EY025202 · NEI · NORTHWESTERN UNIVERSITY AT CHICAGO · PI Gregory William Schwartz · 2015 to 2026
$1.4M
NEI NIH HHS R01 EY013178NEI NIH HHS R01 EY019949NEI NIH HHS R01 EY026078NEI NIH HHS R01 EY028304NEI NIH HHS R01 EY029121NEI NIH HHS R44 EY026466NEI NIH HHS T32 EY025202NEI NIH HHS U01 EY033001
6 · The paper itself

Abstract

Increases in speed and sensitivity enabled rapid clinical adoption of optical coherence tomography (OCT) in ophthalmology. Recently, visible-light OCT (vis-OCT) achieved ultrahigh axial resolution, improved tissue contrast, and provided new functional imaging capabilities, demonstrating the potential to improve clinical care further. However, limited speed and sensitivity caused by the high relative intensity noise (RIN) in supercontinuum lasers impeded the clinical adoption of vis-OCT. To overcome these limitations, we developed balanced-detection vis-OCT (BD-vis-OCT), which uses two calibrated spectrometers to cancel RIN and other noises. We analyzed the RIN to achieve robust subpixel calibration between the two spectrometers and showed that BD-vis-OCT reduced the A-line noise floor by up to 20.5 dB. Metrics comparing signal-to-noise-ratios showed similar image qualities across multiple reference arm powers, a hallmark of operation near the shot-noise limit. We imaged healthy human retinas at an A-line rate of 125 kHz and a field-of-view up to 10 mm ×4 mm. We found that BD-vis-OCT revealed retinal anatomical features previously obscured by the noise floor.

Indexed as

RetinaTomography, Optical CoherenceCalibrationHumansLightSignal-To-Noise Ratio

Identifiers

PMID35089857
PMCPMC9921460

What OpenQuestion holds

Textmetadata
LicenceTDM
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.