Evidence map›Paper›PMID 35088131›Full record

ArticleAnalytical and bioanalytical chemistry2022

A pump-free microfluidic device for fast magnetic labeling of ischemic stroke biomarkers.

Briliant Adhi Prabowo, Elisabete Fernandes, Paulo Freitas

Abstract read
PubMed Publisher
In one paragraph

Article in Analytical and bioanalytical chemistry, 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 5 papers.

0numbers the graph read from it
0cells of the map it votes in
5citing papers in PubMed
2.0field-weighted citation impact, top 15% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

5 citing papers in PubMed, 25 citations in OpenAlex.

  1. Review
  2. Review
  3. Review
  4. Article
  5. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

3 authors at 1 institution in 1 country.

Briliant Adhi PrabowoINL - International Iberian Nanotechnology Laboratory, Av. Mestre José Veiga, s/n 4715-330, Braga, Portugal.ORCID http://orcid.org/0000-0002-7543-5143
Elisabete FernandesINL - International Iberian Nanotechnology Laboratory, Av. Mestre José Veiga, s/n 4715-330, Braga, Portugal. elisabete.fernandes@inl.int.ORCID http://orcid.org/0000-0003-4558-7047
Paulo FreitasINL - International Iberian Nanotechnology Laboratory, Av. Mestre José Veiga, s/n 4715-330, Braga, Portugal. paulo.freitas@inl.int.ORCID http://orcid.org/0000-0003-0015-1186
International Iberian Nanotechnology Laboratory · PT

Funding

Fundacaoo para a Ciencia e a Tecnologia PTDC/MEC-URG/29561/2017
6 · The paper itself

Abstract

This research proposes a low-cost and simple operation microfluidic chip to enhance the magnetic labeling efficiency of two ischemic stroke biomarkers: cellular fibronectin (c-Fn) and matrix metallopeptidase 9 (MMP9). This fully portable and pump-free microfluidic chip is operated based on capillary attractions without any external power source and battery. It uses an integrated cellulose sponge to absorb the samples. At the same time, a magnetic field is aligned to hold the target labeled by the magnetic nanoparticles (MNPs) in the pre-concentrated chamber. By using this approach, the specific targets are labeled from the beginning of the sampling process without preliminary sample purification. The proposed study enhanced the labeling efficiency from 1 h to 15 min. The dynamic interactions occur in the serpentine channel, while the crescent formation of MNPs in the pre-concentrated chamber, acting as a magnetic filter, improves the biomarker-MNP interaction. The labeling optimization by the proposed device influences the dynamic range by optimizing the MNP ratio to fit the linear range across the clinical cutoff value. The limits of detection (LODs) of 2.8 ng/mL and 54.6 ng/mL of c-Fn measurement were achieved for undiluted and four times dilutions of MNP, respectively. While for MMP9, the LODs were 11.5 ng/mL for undiluted functionalized MNP and 132 ng/mL for four times dilutions of functionalized MNP. The results highlight the potential use of this device for clinical sample preparation and specific magnetic target labeling. When combined with a detection system, it could also be used as an integrated component of a point-of-care platform.

Indexed as

Ischemic StrokeLab-On-A-Chip DevicesBiomarkersHumansMagnetic PhenomenaMicrofluidicsBiomarkersFibronectinMagnetic nanoparticleMagnetoresistiveMicrofluidicMMP9Sample preparation

Identifiers

PMID35088131
OpenAlexW4220746814

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked