Evidence map›Paper›PMID 35086969›Full record

Trial reportThe Korean journal of gastroenterology = Taehan Sohwagi Hakhoe chi2022

[Comparison of Clinical Performance and Safety between Domestic New Pull-type Triple-lumen Sphincterotome and Conventional Sphincterotome: A Prospective Multicenter Trial].

Se Woo Park, Sung Ill Jang, Moon Jae Chung, Jae Hee Cho, Seungmin Bang

Open access · goldAbstract readMulticenter StudyRandomized Controlled Trial
In one paragraph

Trial report in The Korean journal of gastroenterology = Taehan Sohwagi Hakhoe chi, 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
0.2field-weighted citation impact, top 55% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed, 1 citations in OpenAlex.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors at 1 institution in 1 country.

Se Woo ParkDivision of Gastroenterology, Department of Internal Medicine, Hallym University Dongtan Sacred Heart Hospital, Hallym University College of Medicine, Hwaseong, Korea.
Sung Ill JangDivision of Gastroenterology, Department of Internal Medicine, Gangnam Severance Hospital, Yonsei University College of Medicine, Seoul, Korea.
Moon Jae ChungDivision of Gastroenterology, Department of Internal Medicine, Severance Hospital, Yonsei University College of Medicine, Seoul, Korea.
Jae Hee ChoDivision of Gastroenterology, Department of Internal Medicine, Gangnam Severance Hospital, Yonsei University College of Medicine, Seoul, Korea.ORCID 0000-0003-4174-0091
Seungmin BangDivision of Gastroenterology, Department of Internal Medicine, Severance Hospital, Yonsei University College of Medicine, Seoul, Korea.
Yonsei University · KR

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

BACKGROUND/

aimsSphincterotomes are essential for endoscopic sphincterotomy (EST) and can also be used for cannulation in ERCP. A domestic new pull-type sphincterotome (Optimos™, Taewoong, Goyang, Korea) provides acceptable technical feasibility and safety, but there are no comparison results. Thus, this study compared the clinical performance and safety of Optimos™ sphincterotome to a conventional sphincterotome (CleverCut3™, Olympus, Tokyo, Japan) in patients who underwent ERCP.

methodsFrom April 2021 to July 2021, a randomized prospective comparative study was conducted on 104 consecutive patients who underwent ERCP in three medical centers. The primary endpoint was the clinical performance and safety of sphincterotomes during ERCP.

resultsOne hundred and four patients were assigned randomly to the Optimos™ group (n=51) or CleverCut3™ group (n=53). All demographic characteristics did not differ between the groups except the BMI. The technical success rate for cannulation, performance of EST, and total procedure time were similar in the two groups. The adverse events did not differ, even though two cases of post-ERCP pancreatitis occurred in CleverCut3™. On the other hand, in questionnaire analysis, CleverCut™ showed a better user's convenience (median [interquartile range] 4.0 [3.0-4.0] vs. 3.0 [3.0-4.0], p=0.013) and manipulability (median [interquartile range], 4.0 [3.0-4.0] vs. 3.0 [3.0-4.0], p=0.039) than Optimos™, even though the other profiles did not reveal any differences.

conclusionsNew domestic pull-type sphincterotome can offer comparable clinical performance and safety profiles to conventional sphincterotome, but it needs refinements to increase the user's convenience and manipulability. Further improvement and innovation will be required to advance domestic medical devices.

Indexed as

Cholangiopancreatography, Endoscopic RetrogradePancreatitisCatheterizationHumansProspective StudiesSphincterotomy, EndoscopicTreatment OutcomeCholangiopancreatography, endoscopic retrogradeDomesticSafetySphincterotomy, endoscopic

Identifiers

PMID35086969
PMCPMC12286493
OpenAlexW4210516970

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.