ArticleInternational journal of spine surgery2021
Two-Year Outcomes From a Prospective Multicenter Investigation Device Trial of a Novel Conformal Mesh Interbody Fusion Device.
Article in International journal of spine surgery, 2021. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
2 citing papers in PubMed, 5 citations in OpenAlex.
- Reduction of degenerative anterolisthesis using an expandable interbody device.Journal of spine surgery (Hong Kong) · 2025Article
- Two-Year Clinical and Radiographic Outcomes for Percutaneous Lumbar Interbody Fusion With an Expandable Titanium Cage Through Kambin's Triangle Without Facetectomy.International journal of spine surgery · 2023Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
9 authors at 6 institutions in 1 country.
Funding
No grant is acknowledged in the PubMed record.
Abstract
backgroundInterbody fusion is a widely utilized and accepted procedure to treat advanced debilitating lumbar degenerative disc disease (DDD). Increasingly, surgeons are seeking interbody devices that are large for stability and grafting purposes but can be inserted with less invasive techniques. To achieve these contrary objectives a novel, conformable mesh interbody fusion device was designed to be placed in the disc space through a small portal and filled with bone graft in situ to a large size. This design can reduce the risk of trauma to surrounding structures while creating a large graft footprint that intimately contours to the patient's own anatomy. The purpose of this Investigational Device Exempt (IDE) trial was to evaluate the perioperative and long-term results of this novel conformable mesh interbody fusion device.
methodsThis investigation is a prospective, multicenter, single-arm, Food and Drug Administration and Institutional Review Board-approved IDE, performance goal trial. A total of 102 adults presenting with DDD at a single level between L2 and S1 and unresponsive to 6 months conservative care had instrumented lumbar interbody fusion. Validated assessment tools include 100 mm visual analog scale for pain, Oswestry Disability Index (ODI) for function, single question survey for patient satisfaction, and computed tomography (CT) scan for fusion. Patients were enrolled across 10 geographically distributed sites. Pain/ODI surveys, physical evaluations, and imaging were performed serially through 24 months. Specifically, CT was performed at 12 and, if not fused, 24 months. Independent radiologists assessed CTs for fusion. An independent committee adjudicated adverse events. Patients with complete data at 24 months were included in the analysis.
resultsNinety-six (96, 94% follow-up rate) patients (57.0 ± 12.0 years, 50.0% female, Body Mass Index 30.6 ± 4.9) reported average decreased low back pain from baseline of 45.0 ± 26.6 at 6 weeks and 51.4 ± 26.2 at 24 months. Right/left leg pain reduced by 28.9 ± 36.7/37.8±32.4 at 6 weeks and 30.5±33.0/40.3 34.6 at 24 months. Mean ODI improved 17.1 ± 18.7 from baseline to 6 weeks and 32.0 ± 18.5 by 24 months. At 24 months, 91.7% of patients rated their procedure as excellent/good. Fusion rates were 97.9% (94/96) at 12 months, and 99% (95/96) at 24 months. Mean operative time, estimated blood loss, and length of stay were 2.6 ± 0.9 hours, 137 ± 217 mL, and 2.3 ± 1.2 days, respectively. No device-related serious adverse events have occurred.
conclusionsClinically significant outcomes for pain, function, fusion, and device safety were demonstrated in this population. Substantial clinical improvements occur by 6 weeks postoperative and continue to improve to 24 months. The successful outcomes observed in this trial support use of this novel device in an instrumented lumbar interbody fusion. LEVEL OF EVIDENCE: 3. CLINICAL RELEVANCE: This reports substantiates that the preliminary 1-year findings published earlier for this investigation are confirmed and the fusion rates and that patient improvements reported are sustained through 2 years.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.