ArticleBMC musculoskeletal disorders2022
Functional outcomes before and after implant removal in patients with posttraumatic shoulder stiffness and healed proximal humerus fractures: does implant material (PEEK vs. titanium) have an impact? - a pilot study.
Article in BMC musculoskeletal disorders, 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 5 papers, 1 of them a synthesis that pooled it.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
5 citing papers in PubMed, 1 synthesis or guideline pooled it, 4 citations in OpenAlex.
- Comparison between CFR-PEEK and titanium plate for proximal humeral fracture: A meta-analysis.Joint diseases and related surgery · 2024Pooled it
- Gene expression and histological assessment of capsular fibrosis in post-traumatic shoulder stiffness following plate fixation of proximal humeral fractures: an exploratory pilot study.BMC musculoskeletal disorders · 2026Article
- Control Group Selection in Preclinical Rat Bone Defect Models: A Systematic Review.Journal of functional biomaterials · 2026Review
- 3D Bioprinting in Limb Salvage Surgery.Journal of functional biomaterials · 2024Review
- Patient satisfaction after removal of locking plates in proximal humeral fractures - worth the surgery under functional and cosmetic aspects?JSES international · 2024Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
9 authors at 2 institutions in 2 countries.
Funding
No grant is acknowledged in the PubMed record.
Abstract
backgroundPosttraumatic shoulder stiffness remains a problem after proximal humerus fracture (PHF) despite good healing rates. The aim of this pilot study was to determine whether the implant material and overlying soft tissue have an effect on shoulder range of motion (ROM) before and after implant removal (IR).
methods16 patients (mean age 55.2 ± 15.3 (SD) years; 62.5% female) were included who underwent operative treatment with locking plates of either carbon fiber reinforced Polyetheretherketone (PEEK) (PEEKPower® humeral fracture plate, Arthrex, Naples, Florida, USA, n = 8) or titanium alloy (Ti) (Philos®, DePuy Synthes, Johnson & Johnson Medical, Raynham, Massachusetts, USA, n = 8) for PHF. All patients presented with a limited ROM and persistent pain in everyday life after the fracture had healed, whereupon IR was indicated. ROM before and after IR were compared as well as the Constant Score (CS) and the CS compared to the contralateral shoulder (%CS) 1 year after IR.
resultsIn group PEEK, elevation was 116.3° ± 19.2° pre- and 129.4° ± 23.7° post-IR (p = 0.027). External rotation was 35.0° ± 7.6° pre- and 50.6° ± 21.8° post-IR (p = 0.041). External rotation with the humerus abducted 90° was 38.8° ± 18.1° pre- and 52.5° ± 25.5° post-IR (p = 0.024). In group Ti, elevation was 110.0° ± 34.6° pre- and 133.8° ± 31.1° post-IR (p = 0.011). External rotation with the humerus at rest was 33.8° ± 23.1° pre- and 48.8° ± 18.7° post-IR (p = 0.048). External rotation with the humerus abducted 90° was 40.0° ± 31.6° pre- and 52.5° ± 22.5° post-IR (p = 0.011). Comparison of the two implant materials showed no significant difference. The overall CS was 90.3 ± 8.8, the %CS was 91.8% ± 14.7%.
conclusionThere was no significant difference in ROM, CS and %CS with respect to plate materials, although lower cell adhesion is reported for the hydrophobic PEEK. However, all patients showed improved functional outcomes after IR in this pilot study. In patients with shoulder stiffness following locked plating for PHF, implants should be removed and open arthrolysis should be performed, independently from the hardware material. LEVEL OF EVIDENCE: II.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.