Evidence map›Paper›PMID 35084671›Full record

ReviewCurrent cardiology reports2022

Interference by Modern Smartphones and Accessories with Cardiac Pacemakers and Defibrillators.

Fahd Nadeem, Cao Thach Tran, Estelle Torbey, Daniel Philbin, Carlos Morales, Michael Wu

Abstract readReview
In one paragraph

Review in Current cardiology reports, 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 6 papers, 1 of them a synthesis that pooled it.

0numbers the graph read from it
0cells of the map it votes in
6citing papers in PubMed, 1 pooled it
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

6 citing papers in PubMed, 1 synthesis or guideline pooled it.

  1. New-generation electronic appliances and cardiac implantable electronic devices: a systematic literature review of mechanisms and in vivo studies.Journal of interventional cardiac electrophysiology : an international journal of arrhythmias and pacing · 2024
    Pooled it
  2. Article
  3. Preventing smartphone induction of magnet mode in cardiac implantable electronic devices.Europace : European pacing, arrhythmias, and cardiac electrophysiology : journal of the working groups on cardiac pacing, arrhythmias, and cardiac cellular electrophysiology of the European Society of Cardiology · 2025
    Article
  4. Review
  5. Article
  6. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors.

Fahd NadeemDivision of Cardiology, Department of Medicine, Lifespan Cardiovascular Institute and Brown University, Providence, RI, USA.
Cao Thach TranDivision of Cardiology, Department of Medicine, Lifespan Cardiovascular Institute and Brown University, Providence, RI, USA.
Estelle TorbeyDivision of Cardiology, Department of Medicine, Lifespan Cardiovascular Institute and Brown University, Providence, RI, USA.
Daniel PhilbinDivision of Cardiology, Department of Medicine, Lifespan Cardiovascular Institute and Brown University, Providence, RI, USA.
Carlos MoralesDivision of Cardiology, Department of Medicine, Lifespan Cardiovascular Institute and Brown University, Providence, RI, USA.
Michael WuDivision of Cardiology, Department of Medicine, Lifespan Cardiovascular Institute and Brown University, Providence, RI, USA. Michael.Wu@lifespan.org.ORCID 0000-0002-0233-0957

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

purpose of reviewThe risk of cardiac implantable electronic device (CIED) interference from cell phones was previously thought to be low based on older studies. Current generation of smartphones have incorporated more magnets for optimization of wireless charging, attachment of accessories, and convenience functionalities. These magnets have the potential to cause CIEDs to inadvertently revert into magnet mode. The purpose of this review is to summarize recent findings on smartphones and their accessories causing interference on CIEDs. RECENT

findingsRecent reports have demonstrated that the iPhone 12 series and accessories have the capability to cause CIED magnetic interference. Current generation of smartphones, smartwatches, wireless headphones, and accessories have the potential to cause CIEDs to revert into magnet mode in both in vivo and ex vivo experiments. The risk of a clinically significant event is unlikely as long as the Food and Drug Administration (FDA) recommendations are followed; keeping smartphones and accessories at least six inches away from CIEDs.

Indexed as

Defibrillators, ImplantablePacemaker, ArtificialHeartHumansSmartphoneHall-effect sensorImplantable cardioverter/defibrillatorMagnetPacemakerReed switchSmartphone