ArticleEndoscopic ultrasound
Adverse events associated with AXIOS stents: Insights from the manufacturer and user facility device experience database.
Article in Endoscopic ultrasound. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 11 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
11 citing papers in PubMed.
- Inadvertent placement of an AXIOSRadiology case reports · 2025Article
- A Critical Narrative Review of Coaxial Double-Pigtail Stenting Within the LAMS in the Management of Pancreatic Fluid Collections.Medicina (Kaunas, Lithuania) · 2025Review
- Evaluation of Advanced Endoscopic Stents for Pancreatic Pseudocyst Drainage: A 2-Year Study.Medical journal of the Islamic Republic of Iran · 2025Article
- Perforation of pancreatic pseudocyst diagnosed with endoscopy and treated with percutaneous drainage.DEN open · 2024Article
- Duodenal hematoma following endoscopic duodenal biopsy in an adult requiring arterial embolization and surgical evacuation: a case report and review of the literature.Frontiers in gastroenterology (Lausanne, Switzerland) · 2024Article
- Small bowel obstruction due to a migrated pyloric stent.Trauma surgery & acute care open · 2024Article
- Organoids to Remodel SARS-CoV-2 Research: Updates, Limitations and Perspectives.Aging and disease · 2023Review
- Endoscopic Treatment of Acute Cholelithiasis Using AXIOS Stenting and Lithotripsy: A Case Series.Cureus · 2023Article
- EUS-guided interventional therapies for pancreatic diseases.Frontiers in medicine · 2023Review
- Clinical application and follow-up of electrocautery-enhanced lumen-apposing metal stents for endoscopic ultrasonography-guided interventions.Annals of medicine · 2023Review
- A novel lumen-apposing metal stent for endoscopic drainage of symptomatic pancreatic fluid collections: a retrospective study.Endoscopic ultrasoundArticle
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
5 authors.
Funding
No grant is acknowledged in the PubMed record.
Abstract
Background and Objectives: The AXIOS stent is indicated for transgastric or transduodenal drainage of symptomatic pancreatic pseudocysts and symptomatic walled off necrosis. The AXIOS stent functions as a conduit which allows solid and liquid pancreatic fluid collections (PFC) contents to pass into the luminal GI tract and also allows the passage of standard and therapeutic endoscopes into the PFC to perform endoscopic debridement. We aim to investigate the number and type of complications associated with AXIOS stents. Materials and Methods: We analyzed postmarketing surveillance data from the Food and Drug Administration Manufacturer and User Facility Device Experience (MAUDE) database January 2016 to February 2021. Results: During the study period, approximately 588 reports with 579 device issues and 250 patient complications were identified. Most device complications were due to stent positioning problems or stent malpositioning (n = 206; 35.6%), followed by stent migration (n = 72; 12.4%), premature deployment (n = 61; 10.5%), material integrity (n = 56; 9.6%), deployment failure (n = 47; 8.1%), and difficulty removing the stent (n = 45; 7.7%). The most reported patient adverse events were hemorrhage/bleeding (n = 81; 32.4%), perforation (n = 26; 10.4%), pain (n = 22; 8.8%), unspecified infection (n = 20; 8.0%), and death (n = 17; 6.8%). Conclusions: Findings from the MAUDE database highlight patient and device complications which endoscopists should be aware of before AXIOS stent placement.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.