Evidence map›Paper›PMID 35083748›Full record

ArticleArtificial organs2022

A computational framework for post-TAVR cardiac conduction abnormality (CCA) risk assessment in patient-specific anatomy.

Symon Reza, Matteo Bianchi, Brandon Kovarovic, Salwa Anam, Marvin J Slepian, Ashraf Hamdan, Rami Haj-Ali, Danny Bluestein

Open access · greenAbstract read
In one paragraph

Article in Artificial organs, 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 7 papers.

0numbers the graph read from it
0cells of the map it votes in
7citing papers in PubMed
1.8field-weighted citation impact, top 14% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

7 citing papers in PubMed, 12 citations in OpenAlex.

  1. Article
  2. Article
  3. Review
  4. Frontiers in bioengineering and biotechnology · 2026
    Article
  5. Article
  6. Article
  7. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

8 authors at 4 institutions in 2 countries.

Symon RezaDepartment of Biomedical Engineering, Stony Brook University, Stony Brook, New York, USA.ORCID https://orcid.org/0000-0003-0225-7726
Matteo BianchiDepartment of Biomedical Engineering, Stony Brook University, Stony Brook, New York, USA.
Brandon KovarovicDepartment of Biomedical Engineering, Stony Brook University, Stony Brook, New York, USA.ORCID https://orcid.org/0000-0002-3995-8262
Salwa AnamDepartment of Biomedical Engineering, Stony Brook University, Stony Brook, New York, USA.
Marvin J SlepianDepartment of Biomedical Engineering, University of Arizona, Tucson, Arizona, USA.ORCID https://orcid.org/0000-0002-7864-6691
Ashraf HamdanDepartment of Cardiology, Rabin Medical Center, Petah Tikva, Israel.
Rami Haj-AliSchool of Mechanical Engineering, Faculty of Engineering, Tel-Aviv University, Tel-Aviv, Israel.
Danny BluesteinDepartment of Biomedical Engineering, Stony Brook University, Stony Brook, New York, USA.ORCID https://orcid.org/0000-0002-4014-2308
Stony Brook University · USRabin Medical Center · ILTel Aviv University · ILUniversity of Arizona · US

Funding

Biomechanical Approaches and Technologies for Enhancing TAVR OutcomesU01EB026414 · NIBIB · STATE UNIVERSITY NEW YORK STONY BROOK · PI BLUESTEIN, DANNY · 2018 to 2022
$3.8M
NIBIB NIH HHS U01 EB026414NIH-NIBIB U01EB026414
6 · The paper itself

Abstract

backgroundCardiac conduction abnormality (CCA)- one of the major persistent complications associated with transcatheter aortic valve replacement (TAVR) may lead to permanent pacemaker implantation. Localized stresses exerted by the device frame on the membranous septum (MS) which lies between the aortic annulus and the bundle of His, may disturb the cardiac conduction and cause the resultant CCA. We hypothesize that the area-weighted average maximum principal logarithmic strain (AMPLS) in the MS region can predict the risk of CCA following TAVR.

methodsRigorous finite element-based analysis was conducted in two patients (Balloon expandable TAVR recipients) to assess post-TAVR CCA risk. Following the procedure one of the patients required permanent pacemaker (PPM) implantation while the other did not (control case). Patient-specific aortic root was modeled, MS was identified from the CT image, and the TAVR deployment was simulated. Mechanical factors in the MS region such as logarithmic strain, contact force, contact pressure, contact pressure index (CPI) and their time history during the TAVR deployment; and anatomical factors such as MS length, implantation depth, were analyzed.

resultsMaximum AMPLS (0.47 and 0.37, respectively), contact force (0.92 N and 0.72 N, respectively), and CPI (3.99 and 2.86, respectively) in the MS region were significantly elevated in the PPM patient as compared to control patient.

conclusionElevated stresses generated by TAVR devices during deployment appear to correlate with CCA risk, with AMPLS in the MS region emerging as a strong predictor that could be used for preprocedural planning in order to minimize CCA risk.

Indexed as

Aortic Valve StenosisHeart Valve ProsthesisPacemaker, ArtificialTranscatheter Aortic Valve ReplacementAortic ValveCardiac Pacing, ArtificialHumansRisk AssessmentRisk FactorsTreatment Outcomeaortic stenosiscardiac conduction abnormalityfinite element analysispermanent pacemakerpermanent pacemaker implantationtranscatheter aortic valve implantationtranscatheter aortic valve replacement

Identifiers

PMID35083748
PMCPMC9187588
OpenAlexW4210681900

What OpenQuestion holds

Textmetadata
LicenceTDM
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.