Evidence map›Paper›PMID 35081674›Full record

ArticleObstetrics & gynecology science2022

Technique for transvaginal removal of large specimen using an Alexis Contained Extraction System during laparoscopic hysterectomy.

Iori Kisu, Kouji Banno, Asahi Tokuoka, Keigo Yamaguchi, Kunio Tanaka, Tetsuro Shiraishi, Kanako Nakamura, Hiroshi Senba, Kiyoko Matsuda, Nobumaru Hirao

Open access · diamondAbstract read
In one paragraph

Article in Obstetrics & gynecology science, 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
0.9field-weighted citation impact, top 29% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed, 4 citations in OpenAlex.

  1. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

10 authors at 2 institutions in 1 country.

Iori KisuDepartment of Obstetrics and Gynecology, Federation of National Public Service Personnel Mutual Aid Associations, Tachikawa Hospital, Tokyo, Japan.
Kouji BannoKeio University School of Medicine, Tokyo, Japan.
Asahi TokuokaDepartment of Obstetrics and Gynecology, Federation of National Public Service Personnel Mutual Aid Associations, Tachikawa Hospital, Tokyo, Japan.
Keigo YamaguchiDepartment of Obstetrics and Gynecology, Federation of National Public Service Personnel Mutual Aid Associations, Tachikawa Hospital, Tokyo, Japan.
Kunio TanakaDepartment of Obstetrics and Gynecology, Federation of National Public Service Personnel Mutual Aid Associations, Tachikawa Hospital, Tokyo, Japan.
Tetsuro ShiraishiDepartment of Obstetrics and Gynecology, Federation of National Public Service Personnel Mutual Aid Associations, Tachikawa Hospital, Tokyo, Japan.
Kanako NakamuraDepartment of Obstetrics and Gynecology, Federation of National Public Service Personnel Mutual Aid Associations, Tachikawa Hospital, Tokyo, Japan.
Hiroshi SenbaDepartment of Obstetrics and Gynecology, Federation of National Public Service Personnel Mutual Aid Associations, Tachikawa Hospital, Tokyo, Japan.
Kiyoko MatsudaDepartment of Obstetrics and Gynecology, Federation of National Public Service Personnel Mutual Aid Associations, Tachikawa Hospital, Tokyo, Japan.
Nobumaru HiraoDepartment of Obstetrics and Gynecology, Federation of National Public Service Personnel Mutual Aid Associations, Tachikawa Hospital, Tokyo, Japan.
Tachikawa Hospital · JPKeio University · JP

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

objectiveTransvaginal removal of large specimens during laparoscopic hysterectomy can be a complex surgical procedure that poses a risk of organ injury and tissue spillage into the abdominal cavity and is associated with extraction of the specimen and manual morcellation. Our objective was to demonstrate a technique for transvaginal removal of large specimens using the Alexis Contained Extraction System (CES) in laparoscopic hysterectomy.

methodsThe technique used for transvaginal removal of large specimens using the Alexis CES was presented in this video. Surgery was performed at a tertiary hospital.

resultsFollowing resection of the specimen during laparoscopic hysterectomy, the Alexis CES was inserted into the abdominal cavity through the umbilical trocar wound. The specimen was placed in a bag to prevent tissue spillage. The ring retractor was guided to the vagina and pulled out transvaginally. By repeatedly turning the ring retractor, tension was applied to the specimen bag, and the vaginal wall was unfolded all around to enable a secure surgical field. During manual morcellation of the specimen in the bag, the retractor was pulled and additionally turned to roll and re-tension the specimen bag when the bag was loosened. The specimen was pushed out of the vagina and safely and effectively extracted without concerns about tissue spillage in the abdominal cavity or related organ injuries.

conclusionThe technique for transvaginal removal of large specimens using the Alexis CES enables simple, effective, and safe tissue extraction with contained manual morcellation during laparoscopic hysterectomy.

Indexed as

HysterectomyLaparoscopyMorcellation

Identifiers

PMID35081674
PMCPMC9119728
OpenAlexW4210468661

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.