Evidence map›Paper›PMID 35080771›Full record

SynthesisThe Cochrane database of systematic reviews2022

Cephalomedullary nails versus extramedullary implants for extracapsular hip fractures in older adults.

Sharon R Lewis, Richard Macey, James R Gill, Martyn J Parker, Xavier L Griffin

Open access · bronzeAbstract readSystematic Review
In one paragraph

Synthesis in The Cochrane database of systematic reviews, 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 39 papers, 11 of them syntheses that pooled it.

0numbers the graph read from it
0cells of the map it votes in
39citing papers in PubMed, 11 pooled it
13.1field-weighted citation impact, top 1% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

39 citing papers in PubMed, 11 syntheses or guidelines pooled it, 62 citations in OpenAlex.

  1. Pooled it
  2. Pooled it
  3. Pooled it
  4. Pooled it
  5. Pooled it
  6. Pooled it
  7. Pooled it
  8. Pooled it
  9. Arthroplasties for hip fracture in adults.The Cochrane database of systematic reviews · 2022
    Pooled it
  10. Pooled it
  11. Pooled it
  12. Trial
  13. Trial
  14. Trial
  15. Article
  16. Article
  17. Article
  18. [Pertrochanteric fractures].Unfallchirurgie (Heidelberg, Germany) · 2026
    Review
  19. Comparison of the Dynamic Cut-Out Failure Modes of Common Proximal Femoral Fixation Devices Using a Mesh-Free Computational Method.Journal of orthopaedic research : official publication of the Orthopaedic Research Society · 2026
    Article
  20. Review
4 · The record

Corrections and comments

5 · Who and what money

Authors and funding

5 authors at 5 institutions in 1 country.

Sharon R LewisBone and Joint Health, Blizard Institute, Queen Mary University of London, London, UK.
Richard MaceyNuffield Department of Orthopaedics, Rheumatology and Musculoskeletal Sciences (NDORMS), University of Oxford, Oxford, UK.
James R GillDepartment of Trauma and Orthopaedics, Cambridge University Hospitals, Cambridge, UK.
Martyn J ParkerDepartment of Orthopaedics, Peterborough and Stamford Hospitals NHS Foundation Trust, Peterborough, UK.
Xavier L GriffinBone and Joint Health, Blizard Institute, Queen Mary University of London, London, UK.
Barts Health NHS Trust · GBCambridge University Hospitals NHS Foundation Trust · GBPeterborough and Stamford Hospitals NHS Foundation Trust · GBQueen Mary University of London · GBUniversity of Oxford · GB

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

backgroundHip fractures are a major healthcare problem, presenting a substantial challenge and burden to patients, healthcare systems and society. The increased proportion of older adults in the world population means that the absolute number of hip fractures is rising rapidly across the globe. Most hip fractures are treated surgically. This Cochrane Review evaluates evidence for implants used to treat extracapsular hip fractures.

objectivesTo assess the relative effects of cephalomedullary nails versus extramedullary fixation implants for treating extracapsular hip fractures in older adults. SEARCH

methodsWe searched CENTRAL, MEDLINE, Embase, Web of Science, the Cochrane Database of Systematic Reviews, Epistemonikos, ProQuest Dissertations & Theses, and the National Technical Information Service in July 2020. We also searched clinical trials databases, conference proceedings, reference lists of retrieved articles, and conducted backward-citation searches. SELECTION CRITERIA: We included randomised controlled trials (RCTs) and quasi-RCTs comparing cephalomedullary nails with extramedullary implants for treating fragility extracapsular hip fractures in older adults. We excluded studies in which all or most fractures were caused by a high-energy trauma or specific pathologies other than osteoporosis. DATA COLLECTION AND ANALYSIS: We used standard methodological procedures expected by Cochrane. We collected data for seven critical outcomes: performance of activities of daily living (ADL), delirium, functional status, health-related quality of life, mobility, mortality (reported within four months of surgery as 'early mortality'; and reported from four months onwards, with priority given to data at 12 months, as '12 months since surgery'), and unplanned return to theatre for treating a complication resulting directly or indirectly from the primary procedure (such as deep infection or non-union). We assessed the certainty of the evidence for these outcomes using GRADE.  MAIN

resultsWe included 76 studies (66 RCTs, 10 quasi-RCTs) with a total of 10,979 participants with 10,988 extracapsular hip fractures. The mean ages of participants in the studies ranged from 54 to 85 years; 72% were women. Seventeen studies included unstable trochanteric fractures; three included stable trochanteric fractures only; one included only subtrochanteric fractures; and other studies included a mix of fracture types. More than half of the studies were conducted before 2010. Owing to limitations in the quality of reporting, we could not easily judge whether care pathways in these older studies were comparable to current standards of care. We downgraded the certainty of the outcomes because of high or unclear risk of bias; imprecision (when data were available from insufficient numbers of participants or the confidence interval (CI) was wide); and inconsistency (when we noted substantial levels of statistical heterogeneity or differences between findings when outcomes were reported using other measurement tools). There is probably little or no difference between cephalomedullary nails and extramedullary implants in terms of mortality within four months of surgery (risk ratio (RR) 0.96, 95% CI 0.79 to 1.18; 30 studies, 4603 participants) and at 12 months (RR 0.99, 95% CI 0.90 to 1.08; 47 studies, 7618 participants); this evidence was assessed to be of moderate certainty. We found low-certainty evidence for differences in unplanned return to theatre but this was imprecise and included clinically relevant benefits and harms (RR 1.15, 95% CI 0.89 to 1.50; 50 studies, 8398 participants). The effect estimate for functional status at four months also included clinically relevant benefits and harms; this evidence was derived from only two small studies and was imprecise (standardised mean difference (SMD) 0.02, 95% CI -0.27 to 0.30; 188 participants; low-certainty evidence). Similarly, the estimate for delirium was imprecise (RR 1.22, 95% CI 0.67 to 2.22; 5 studies, 1310 participants; low-certainty evidence). Mobility at four months was reported using different measures (such as the number of people with independent mobility or scores on a mobility scale); findings were not consistent between these measures and we could not be certain of the evidence for this outcome. We were also uncertain of the findings for performance in ADL at four months; we did not pool the data from four studies because of substantial heterogeneity. We found no data for health-related quality of life at four months. Using a cephalomedullary nail in preference to an extramedullary device saves one superficial infection per 303 patients (RR 0.71, 95% CI 0.53 to 0.96; 35 studies, 5087 participants; moderate-certainty evidence) and leads to fewer non-unions (RR 0.55, 95% CI 0.32 to 0.96; 40 studies, 4959 participants; moderate-certainty evidence). However, the risk of intraoperative implant-related fractures was greater with cephalomedullary nails (RR 2.94, 95% CI 1.65 to 5.24; 35 studies, 4872 participants; moderate-certainty evidence), as was the risk of later fractures (RR 3.62, 95% CI 2.07 to 6.33; 46 studies, 7021 participants; moderate-certainty evidence). Cephalomedullary nails caused one additional implant-related fracture per 67 participants. We noted no evidence of a difference in other adverse events related or unrelated to the implant, fracture or both. Subgroup analyses provided no evidence of differences between the length of cephalomedullary nail used, the stability of the fracture, or between newer and older designs of cephalomedullary nail. AUTHORS'

conclusionsExtramedullary devices, most commonly the sliding hip screw, yield very similar functional outcomes to cephalomedullary devices in the management of extracapsular fragility hip fractures. There is a reduced risk of infection and non-union with cephalomedullary nails, however there is an increased risk of implant-related fracture that is not attenuated with newer designs. Few studies considered patient-relevant outcomes such as performance of activities of daily living, health-related quality of life, mobility, or delirium. This emphasises the need to include the core outcome set for hip fracture in future RCTs.

Indexed as

Fracture Fixation, IntramedullaryHip FracturesAgedAged, 80 and overBone NailsFemaleFracture Fixation, InternalHumansMiddle AgedNailsSystematic Reviews as Topic

Identifiers

PMID35080771
PMCPMC8791231
OpenAlexW4210550128

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.