ArticleScientific reports2022
Integrated deep learning framework for accelerated optical coherence tomography angiography.
Article in Scientific reports, 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 14 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
14 citing papers in PubMed, 25 citations in OpenAlex.
- Mixture-of-Skip-Connection Deep Learning Model to Classify Stroke Severity from Diffusion Weighted Imaging Based on NIHSS.Journal of imaging informatics in medicine · 2026Article
- Artificial intelligence in ophthalmology clinical trials: a narrative review.Graefe's archive for clinical and experimental ophthalmology = Albrecht von Graefes Archiv fur klinische und experimentelle Ophthalmologie · 2026Review
- Retinal Imaging as a Window into Cardiovascular Health: Towards Harnessing Retinal Analytics for Precision Cardiovascular Medicine.Journal of cardiovascular development and disease · 2025Review
- Three-dimensional C-scan-based generation adversarial network with synthetic input to improve optical coherence tomography angiography.Journal of biomedical optics · 2025Article
- Optical coherence tomography (OCT) and OCT angiography: Technological development and applications in brain science.Theranostics · 2025Review
- Diffusion model based OCT to OCTA translation.Frontiers in medicine · 2025Article
- Improved microvascular imaging with optical coherence tomography using 3D neural networks and a channel attention mechanism.Scientific reports · 2024Article
- Artificial neural network for enhancing signal-to-noise ratio and contrast in photothermal optical coherence tomography.Scientific reports · 2024Article
- Quantitative Characterization of Retinal Features in Translated OCTA.medRxiv : the preprint server for health sciences · 2024Article
- Quantitative characterization of retinal features in translated OCTA.Experimental biology and medicine (Maywood, N.J.) · 2024Article
- Feasibility of deep learning-based polarization-sensitive optical coherence tomography angiography for imaging cutaneous microvasculature.Biomedical optics express · 2023Article
- Using Artificial Intelligence to Analyse the Retinal Vascular Network: The Future of Cardiovascular Risk Assessment Based on Oculomics? A Narrative Review.Ophthalmology and therapy · 2023Review
- Dynamic 3D imaging of cerebral blood flow in awake mice using self-supervised-learning-enhanced optical coherence Doppler tomography.Communications biology · 2023Article
- Optical Coherence Tomography Angiography of the Intestine: How to Prevent Motion Artifacts in Open and Laparoscopic Surgery?Life (Basel, Switzerland) · 2023Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
5 authors at 2 institutions in 1 country.
Funding
Abstract
Label-free optical coherence tomography angiography (OCTA) has become a premium imaging tool in clinics to obtain structural and functional information of microvasculatures. One primary technical drawback for OCTA, however, is its imaging speed. The current protocols require high sampling density and multiple acquisitions of cross-sectional B-scans to form one image frame, resulting in low acquisition speed. Recently, deep learning (DL)-based methods have gained attention in accelerating the OCTA acquisition process. They achieve faster acquisition using two independent reconstructing approaches: high-quality angiograms from a few repeated B-scans and high-resolution angiograms from undersampled data. While these approaches have shown promising results, they provide limited solutions that only partially account for the OCTA scanning mechanism. Herein, we propose an integrated DL method to simultaneously tackle both factors and further enhance the reconstruction performance in speed and quality. We designed an end-to-end deep neural network (DNN) framework with a two-staged adversarial training scheme to reconstruct fully-sampled, high-quality (8 repeated B-scans) angiograms from their corresponding undersampled, low-quality (2 repeated B-scans) counterparts by successively enhancing the pixel resolution and the image quality. Using an in-vivo mouse brain vasculature dataset, we evaluate our proposed framework through quantitative and qualitative assessments and demonstrate that our method can achieve superior reconstruction performance compared to the conventional means. Our DL-based framework can accelerate the OCTA imaging speed from 16 to 256[Formula: see text] while preserving the image quality, thus enabling a convenient software-only solution to enhance preclinical and clinical studies.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.