ArticleJournal of applied clinical medical physics2022
Accuracy of patient setup positioning using surface-guided radiotherapy with deformable registration in cases of surface deformation.
Article in Journal of applied clinical medical physics, 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 8 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
8 citing papers in PubMed.
- Enhancing patient positioning precision: a comparative analysis of surface-guided radiation therapy systems.Radiological physics and technology · 2025Article
- Cherenkov Imaged Bio-Morphological Features Verify Patient Positioning With Deformable Tissue Translocation in Breast Radiation Therapy.Advances in radiation oncology · 2025Article
- Development of a phantom for assessing the precision of setup in skin mark-less surface-guided radiotherapy.Journal of applied clinical medical physics · 2024Article
- Interfractional variation in whole-breast VMAT irradiation: a dosimetric study with complementary SGRT and CBCT patient setup.Radiation oncology (London, England) · 2024Article
- Surface-guided radiotherapy improves rotational accuracy in gynecological cancer patients.Reports of practical oncology and radiotherapy : journal of Greatpoland Cancer Center in Poznan and Polish Society of Radiation Oncology · 2023Article
- Accuracy of patient setup positioning using surface-guided radiotherapy with deformable registration in cases of surface deformation.Journal of applied clinical medical physics · 2022Article
- Article
- Analysis of Surface Guidance Versus Laser Alignment for Precision Lung Cancer Particle Therapy.Technology in cancer research & treatmentArticle
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
6 authors.
Funding
No grant is acknowledged in the PubMed record.
Abstract
The Catalyst™ HD (C-RAD Positioning AB, Uppsala, Sweden) is surface-guided radiotherapy (SGRT) equipment that adopts a deformable model. The challenge in applying the SGRT system is accurately correcting the setup error using a deformable model when the body of the patient is deformed. This study evaluated the effect of breast deformation on the accuracy of the setup correction of the SGRT system. Physical breast phantoms were used to investigate the relationship between the mean deviation setup error obtained from the SGRT system and the breast deformation. Physical breast phantoms were used to simulate extension and shrinkage deformation (-30 to 30 mm) by changing breast pieces. Three-dimensional (3D) Slicer software was used to evaluate the deformation. The maximum deformations in X, Y, and Z directions were obtained as the differences between the original and deformed breasts. We collected the mean deviation setup error from the SGRT system by replacing the original breast part with the deformed breast part. The mean absolute difference of lateral, longitudinal, vertical, pitch, roll, and yaw, between the rigid and deformable registrations was 2.4 ± 1.7 mm, 1.3 ± 1.2 mm, 6.4 ± 5.2 mm, 2.5° ± 2.5°, 2.2° ± 2.4°, and 1.0° ± 1.0°, respectively. Deformation in the Y direction had the best correlation with the mean deviation translation error (R = 0.949) and rotation error (R = 0.832). As the magnitude of breast deformation increased, both mean deviation setup errors increased, and there was greater error in translation than in rotation. Large deformation of the breast surface affects the setup correction. Deformation in the Y direction most affects translation and rotation errors.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.