Evidence map›Paper›PMID 35076784›Full record

ArticleThe Egyptian heart journal : (EHJ) : official bulletin of the Egyptian Society of Cardiology2022

Comparison of radiation dose and its correlates between coronary computed tomography angiography and invasive coronary angiography in Northeastern Thailand.

Phatraporn Aupongkaroon, Pattarapong Makarawate, Narumol Chaosuwannakit

Open access · diamondAbstract read
In one paragraph

Article in The Egyptian heart journal : (EHJ) : official bulletin of the Egyptian Society of Cardiology, 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 9 papers, 1 of them a synthesis that pooled it.

0numbers the graph read from it
0cells of the map it votes in
9citing papers in PubMed, 1 pooled it
2.4field-weighted citation impact, top 11% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

9 citing papers in PubMed, 1 synthesis or guideline pooled it, 18 citations in OpenAlex.

  1. Pooled it
  2. Article
  3. Article
  4. Article
  5. Review
  6. Article
  7. CT-scan-guided-irrigated trans-catheter ablation of epicardial accessory pathways in the coronary sinus: safety and feasibility in pediatric patients.Journal of interventional cardiac electrophysiology : an international journal of arrhythmias and pacing · 2025
    Article
  8. Article
  9. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

3 authors at 1 institution in 1 country.

Phatraporn AupongkaroonRadiology Department, Faculty of Medicine, Khon Kaen University, Khon Kaen, 40000, Thailand.
Pattarapong MakarawateCardiology Unit, Internal Medicine Department, Faculty of Medicine, Khon Kaen University, Khon Kaen, Thailand.
Narumol ChaosuwannakitRadiology Department, Faculty of Medicine, Khon Kaen University, Khon Kaen, 40000, Thailand. narumol_chao@yahoo.com.ORCID http://orcid.org/0000-0001-9711-5194
Khon Kaen University · TH

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

backgroundThe number of coronary computed tomography angiography (CCTA) exams is steadily growing. A novel computed tomography (CT) system has been developed to increase image quality while lowering patient radiation. The radiation dose attributed to CCTA has received considerable attention, whereas the dose associated with invasive catheter angiography (ICA) has received less. This study aims to investigate the radiation exposure of CCTA in patients and compare it to ICA.

resultsThe mean effective dose of CCTA was 2.88 ± 0.85 mSv which was significantly lower than the mean effective dose of ICA (5.61 ± 0.55 mSv), p < 0.0001. The effective dose of CCTA correlated with the weight, height, and BMI, while the effective dose of ICA was associated with patient weight and BMI. The radiation exposure from CCTA has been considerably reduced over the last ten years by almost 2.5 folds. The mean radiation dose from the newer generation CT used in 2019 was significantly lower than that of the single-source CT in 2010 (2.88 ± 0.85 mSv vs. 7.15 ± 3.4 mSv, p < 0.001).

conclusionsCCTA allows evaluation of CAD with a significantly less effective radiation dose to patients than diagnostic ICA. There was a significant decrease in radiation dose from CCTA over time. Regular measurement of patient doses is an essential step to optimize exposure. It makes operators aware of their performance and allows comparisons with generally accepted practices.

Indexed as

Coronary angiographyCoronary CTACTARadiation dose

Identifiers

PMID35076784
PMCPMC8789964
OpenAlexW4207046886

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.