Evidence map›Paper›PMID 35075811›Full record

ArticleClinical physiology and functional imaging2022

Test-retest reliability of skeletal muscle oxygenation measurement using near-infrared spectroscopy during exercise in patients with sport-related iliac artery flow limitation.

Martijn van Hooff, Eduard J Meijer, Marc R M Scheltinga, Hans H C M Savelberg, Goof Schep

Open access · bronzeAbstract read
In one paragraph

Article in Clinical physiology and functional imaging, 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 10 papers, 1 of them a synthesis that pooled it.

0numbers the graph read from it
0cells of the map it votes in
10citing papers in PubMed, 1 pooled it
4.1field-weighted citation impact, top 6% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

10 citing papers in PubMed, 1 synthesis or guideline pooled it, 19 citations in OpenAlex.

  1. Pooled it
  2. Article
  3. Article
  4. Article
  5. Article
  6. Article
  7. Article
  8. Article
  9. Article
  10. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors at 2 institutions in 1 country.

Martijn van HooffDepartment of Sports and Exercise, Máxima Medical Centre, Veldhoven, Noord-Brabant, The Netherlands.ORCID http://orcid.org/0000-0002-8976-3500
Eduard J MeijerDepartment of Clinical Physics, Máxima Medical Centre, Veldhoven, Noord-Brabant, The Netherlands.ORCID http://orcid.org/0000-0002-4753-8671
Marc R M ScheltingaDepartment of Clinical Physics, Máxima Medical Centre, Veldhoven, Noord-Brabant, The Netherlands.ORCID http://orcid.org/0000-0003-4924-6194
Hans H C M SavelbergDepartment of Movement and Nutrition Sciences, Faculty of Health, Medicine and Life Sciences, Maastricht University Maastricht, Maastricht, The Netherlands.ORCID http://orcid.org/0000-0002-8864-2109
Goof SchepDepartment of Sports and Exercise, Máxima Medical Centre, Veldhoven, Noord-Brabant, The Netherlands.ORCID http://orcid.org/0000-0003-0207-8066
Radboud University Nijmegen · NLMaastricht University · NL

Funding

ZonMw 75020017
6 · The paper itself

Abstract

The ankle-brachial index is an accurate tool for detecting claudication in atherosclerotic patients. However, this technique fails to identify subtle flow limitations of the iliac arteries (FLIA) in endurance athletes. Near-infrared spectroscopy (NIRS) is a noninvasive technique that measures skeletal muscle tissue oxygenation status. The aim of the present study is to examine the absolute and relative test-retest reliability of NIRS and evaluate its potential as a diagnostic tool in FLIA. NIRS-derived exercise variables were analyzed during exercise and recovery in FLIA 17 patients and 19 healthy controls. The relative reliability of absolute variables (such as the maximal value) were slight to yet predominantly substantial (intraclass correlation coefficient [ICC], ICC range: 0.06-0.76) with good to excellent absolute reliability (absolute limits of agreement [ALoA], ALoA range: 0.8 ± 10.2 to 0.7 ± 13.1; coefficient of variation [CV], CV range: 5%-11%). Absolute values encompassing signal amplitudes showed moderate to almost perfect relative reliability (ICC range: 0.51-0.89) and poor to good absolute reliability (ALoA range: -1.3 ± 7.0 to -2.5 ± 15.7; CV range: 15%-32%). Kinetic variables showed moderate to almost perfect relative reliability for most recovery kinetics variables (ICC range: 0.54-0.86) with fair to good absolute reliability (ALoA range: 0.4 ± 12.2 to 3.9 ± 37.9; CV range: 18%-27%). Particularly, kinetic variables showed significant differences between patients and healthy subjects. NIRS is found to be a reliable method for examining muscle tissue oxygenation variables. Given the significant differences in especially recovery kinetics between normal subjects and patients, NIRS may contribute to diagnosing FLIA in endurance athletes.

Indexed as

Iliac ArterySpectroscopy, Near-InfraredExerciseExercise TestHumansMuscle, SkeletalReproducibility of Resultsendofibrosismaximal exercise testingmuscle oxygen saturationnear-infrared spectroscopyreproducibilitytest-retest reliability

Identifiers

PMID35075811
PMCPMC9306874
OpenAlexW4207081529

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC
Read underepoch 390

Registered trials

None linked