Evidence map›Paper›PMID 35075504›Full record

ArticleAesthetic plastic surgery2022

Reoperative Augmentation Mammoplasty: An Algorithm to Optimize Soft-Tissue Support, Pocket Control, and Smooth Implant Stability with Composite Reverse Inferior Muscle Sling (CRIMS) and its Technical Variations.

Alexandre Mendonça Munhoz, Ary de Azevedo Marques Neto, João Maximiliano

Abstract read
PubMed Publisher
In one paragraph

Article in Aesthetic plastic surgery, 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 3 papers.

0numbers the graph read from it
0cells of the map it votes in
3citing papers in PubMed
3.1field-weighted citation impact, top 9% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

3 citing papers in PubMed, 15 citations in OpenAlex.

  1. Article
  2. Article
  3. Article
4 · The record

Corrections and comments

5 · Who and what money

Authors and funding

3 authors at 2 institutions in 1 country.

Alexandre Mendonça MunhozPlastic Surgery Division, Hospital Sírio-Libanês, Rua Mato Grosso, 306 cj.1706 Higienópolis, Sao Paulo, SP, 01239-040, Brazil. alexandremunhoz@hotmail.com.
Ary de Azevedo Marques NetoPlastic Surgery Division, Hospital Sírio-Libanês, Rua Mato Grosso, 306 cj.1706 Higienópolis, Sao Paulo, SP, 01239-040, Brazil.
João MaximilianoBrazilian Society of Plastic Surgery, Sao Paulo, Brazil.
Hospital Sírio-Libanês · BRHospital de Clínicas de Porto Alegre · BR

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

backgroundReoperative augmentation mammoplasty (RAM) is a challenging procedure, with the highest rates of complications and revision. Complications include implant malposition, lateral displacement, bottoming out, and rotation. These deformities can be addressed with various procedures, but the pocket control and stability of the new smooth implant surface may present limitations.

objectivesThis study revisits a previously described predictable approach in primary breast augmentation and defines a surgical treatment algorithm for RAM technique selection.

methodsBetween 2017 and 2021, 72 patients (144 breasts) underwent RAM with composite reverse inferior muscle sling (CRIMS) technique and its technical variations (types I-IV). CRIMS technique involves placing a silicone gel implant into the submuscular (SM) pocket with an inferior sling of the pectoralis major muscle based on the dimensions of the implant, in combination with support points/dermal bridge sutures to stabilize the implant and glandular tissue at the lower breast pole (LBP). Reasons for surgery were ptosis (92%), implant and malposition (59.6%). Patients were followed for at least 6 months in 5 cases (6.9%), at least 12 months in 50 cases (69.4%), for at least 36 months in 10 cases (13.8%), and more than 36 months in 7 cases (9.7%) (mean 34 months; range 6-48 months). Patients were evaluated in terms of resolution of symptoms, satisfaction, and complications. Three-dimensional imaging (3DI) obtained from the Divina scanner system was used and followed up for 1 year to evaluate breast position, lower pole stretch (LPS), and intermammary distance (IMD).

resultsEleven cases of minor complications were observed in 9 patients (12.5%): hypertrophic scarring in 4 (5.5%), wound dehiscence in 4 (5.5%), Baker II/III capsular contracture in 1 (1.3%). SmoothSilk surface silicone implants were used in all cases, with an average volume decrease of 120 cc. Sixty-eight patients (94.4%) were either very satisfied/satisfied with their aesthetic result. Breast images were performed in a group of 65 patients (90.2%), and in 7 breasts (10.7%), localized oil cysts were observed. The value for LPS was 7.87% (p <0.0001) between 10 days and 1 year, with the majority occurring early in the first 3 months, indicating that the LBP/implant remains steady during the last months of follow-up. No cases of fat necrosis/seroma were observed. There were no signs of intra/extracapsular ruptures, capsular contracture. There were 2 cases (3%) of minimal implant displacement and no cases of rotation.

conclusionsCRIMS and its variations can be performed successfully in RAM. An algorithmic approach can facilitate the pre- and intraoperative decision-making process and provide the new pocket control and implant stability with acceptable complication rates. Further accurate evaluation is recommended to understand the benefits or disadvantages of CRIMS compared to other RAM techniques. LEVEL OF EVIDENCE IV: This journal requires that authors assign a level of evidence to each article. For a full description of these Evidence-Based Medicine ratings, please refer to the Table of Contents or the online Instructions to Authors www.springer.com/00266 .

Indexed as

Breast ImplantationBreast ImplantsContractureMammaplastyAlgorithmsEstheticsHumansLipopolysaccharidesPectoralis MusclesRetrospective StudiesTreatment OutcomeLipopolysaccharidesAugmentation mastopexyBreast implantsBreast surgeryComplicationsMastopexyOutcomeReoperationRevisionSurgical technique

Identifiers

PMID35075504
OpenAlexW4207009575

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.