ArticleRadiation oncology (London, England)2022
Monte Carlo simulation of tilted contact plaque brachytherapy placement for juxtapapillary retinoblastoma.
Article in Radiation oncology (London, England), 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. It is linked to trial NCT07530458 (Retinoblastoma Consolidation), which is not on this map. Not yet cited in PubMed.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Retinoblastoma Consolidation: A Retrospective Multivariate Analysis In Egyptian Population
Who cites it
0 citing papers in PubMed, 2 citations in OpenAlex.
No citing paper in PubMed yet.
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
14 authors at 2 institutions in 2 countries.
Funding
Abstract
backgroundThe 106-Ruthenium contact plaque applicator is utilized for the treatment of intraocular tumor within a thickness of less than 6 mm. If anything obstructs the placement of the plaque applicator, the treatment is generally difficult because the applicator has to be temporarily located just on the opposite side of the retinal tumor. Furthermore, the plaque applicator edge of approximately 1 mm does not contain CASE PRESENTATION: We present an infant with retinoblastoma whose tumor involved macular and was invading just temporal side of the optic disc. Additionally, posterior staphyloma was induced by a series of previous treatments, making it more difficult to treat the standard plaque placement. Thus, the applicator type of CCA was intentionally tilted to the eyeball and the distance between the posterior edge of the applicator and the eyeball had to be then equal to or more than 2 mm based on the dose distribution of the applicator calculated using Monte Carlo simulation to minimize damage to surrounding tissues while covering the tumor. It was then comparable to the certification and previous reports. Based on the acquired dose distribution, the optimal placement of the applicator was derived from varying the distance between the applicator's edge and the eyeball, and the distance was then determined to be 2 mm. In this case, the minimum dose rate in the tumor was 25.5 mGy/min, and the time required to deliver the prescribed dose was 26.2 h. Therefore, the tilted
conclusionsOptimizing the placement of the
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.