ArticlePediatric quality & safety
Quality Improvement Methodology Facilitates Adherence to Echocardiogram Protocol Measurements.
Article in Pediatric quality & safety. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
0 citing papers in PubMed, 1 citations in OpenAlex.
No citing paper in PubMed yet.
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
6 authors at 3 institutions in 1 country.
Funding
No grant is acknowledged in the PubMed record.
Abstract
introductionLocal institutional echocardiogram protocols reflect standard measurements as per national guidelines, but adherence to measurements was inconsistent. This inconsistency led to variability in reporting and impacted the use of serial measurements for clinical decision-making. Therefore, we aimed to improve complete adherence to universal and protocol-specific measures for echocardiograms performed for first-time or cardiomyopathy studies from 60% to 90% from July 2019 to February 2020.
methodsWe included all sonographer-performed echocardiograms for first-time or cardiomyopathy protocol studies. We reviewed universal measures and protocol-specific measures for all included studies. We created a scoring system reflecting measurement completion. We used a control chart to measure compliance and established a baseline over 2 months. PDSA cycles over 5 months included interventions such as sonographer education, technical improvements to the measurement toolbar, and group and individual performance feedback.
resultsWe reviewed over 4000 studies-the reporting of complete universal measures improved significantly from a median score of 60% to 93%. Protocol-specific measures for first-time studies also showed significant improvement from 62% to 90% adherence. Cardiomyopathy-specific measures demonstrated 87% adherence at baseline, which improved to 95% but then returned to baseline. Sonographer education and toolbar adjustment prompted special cause variation with further improvement following performance feedback. The universal and first-time protocol measures reached 90% adherence with sustained improvement for over 9 months.
conclusionsWe employed quality improvement methodology to improve complete adherence to echocardiographic protocol measurements, thereby facilitating echocardiographic quality and reporting consistency. We plan to spread these interventions to improve adherence to other protocols.