Evidence map›Paper›PMID 35071468›Full record

ArticleAnnals of translational medicine2021

Self-expandable metallic stent with

Rui An, Hu Zhang, Jing Yu, Yunbao Cao, Jialiang Ren, Wangang Guo, Zhonghua Luo

Abstract read
In one paragraph

Article in Annals of translational medicine, 2021. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers.

0numbers the graph read from it
0cells of the map it votes in
2citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

2 citing papers in PubMed.

  1. Article
  2. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors.

Rui An *Department of Radiology, Xijing Hospital, Fourth Military Medical University, Xi'an, China.
Hu Zhang *Department of Interventional Radiology, Tangdu Hospital, Fourth Military Medical University, Xi'an, China.
Jing YuDepartment of Radiology, Xijing Hospital, Fourth Military Medical University, Xi'an, China.
Yunbao CaoDepartment of Interventional Radiology, Tangdu Hospital, Fourth Military Medical University, Xi'an, China.
Jialiang RenGE Healthcare China, Beijing, China.
Wangang GuoDepartment of Cardiology, Tangdu Hospital, Fourth Military Medical University, Xi'an, China.
Zhonghua LuoDepartment of Interventional Radiology, Tangdu Hospital, Fourth Military Medical University, Xi'an, China.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

backgroundMalignant obstructive jaundice (MOJ) has a low immediate surgery rate (10-20%) and a poor post-resection survival rate. Although several clinical results have demonstrated the safety and efficacy of stent placement combined with radioactive seeds, the existing implantation methods are time consuming and prone to error. In this study, we introduced a self-made delivery system and novel implantation method for a self-expandable metallic stent (SEMS) with

methodsOur self-made delivery system was applied to 61 patients (39 males and 22 females, mean age 66.36±10.73 years) from October 2018 to June 2020 in our center with a novel implantation method. The preparation and manipulation processes were described in detail. Technical and clinical successes were recorded, and stent patency and overall survival (OS) were assessed. A P value of less than 0.05 indicated a significant difference.

resultsStents with

conclusionsOur self-made delivery system with a novel SEMS implantation method with

Indexed as

125I seed strandBiliary stentmalignant obstructive jaundice (MOJ)

Identifiers

PMID35071468
PMCPMC8756205

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC-ND
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.