Evidence map›Paper›PMID 35071214›Full record

ArticleFrontiers in bioengineering and biotechnology2021

Two-Dimensional Photoacoustic/Ultrasonic Endoscopic Imaging Based on a Line-Focused Transducer.

Weiran Pang, Yongjun Wang, Lili Guo, Bo Wang, Puxiang Lai, Jiaying Xiao

Open access · goldAbstract read
In one paragraph

Article in Frontiers in bioengineering and biotechnology, 2021. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 6 papers.

0numbers the graph read from it
0cells of the map it votes in
6citing papers in PubMed
1.1field-weighted citation impact, top 28% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

6 citing papers in PubMed, 14 citations in OpenAlex.

  1. Review
  2. Article
  3. Article
  4. Article
  5. Review
  6. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors at 3 institutions in 2 countries.

Weiran PangDepartment of Biomedical Engineering, School of Basic Medical Science, Central South University, Changsha, China.
Yongjun WangDepartment of Biomedical Engineering, School of Basic Medical Science, Central South University, Changsha, China.
Lili GuoDepartment of Biomedical Engineering, College of Biology, Hunan University, Changsha, China.
Bo WangDepartment of Biomedical Engineering, School of Basic Medical Science, Central South University, Changsha, China.
Puxiang LaiDepartment of Biomedical Engineering, The Hong Kong Polytechnic University, Hong Kong, Hong Kong SAR, China.
Jiaying XiaoDepartment of Biomedical Engineering, School of Basic Medical Science, Central South University, Changsha, China.
Central South University · CNHong Kong Polytechnic University · HKHunan University · CN

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Existing acoustic-resolution photoacoustic/ultrasonic endoscopy (PA/USE) generally employs a point-focused transducer for ultrasound detection, which is only sensitive in its focal region, thus the lateral resolution and sensitivity drop dramatically when the targets move far from its focus. Even if a dynamic focusing algorithm is applied, the sensitivity out of the transducer focus is still much lower than that in the focus in ultrasonic imaging mode. In this work, we propose an acoustic-resolution PA/USE with a line-focused transducer to realize automatic focusing for the first time. In comparison to a point-focused transducer, the line-focused transducer emits a more uniform sound field, causing the original signal intensity and signal-to-noise ratio (SNR) of the front and rear targets to be closer in the radial direction, which is beneficial for improving target signal uniformity in ultrasonic imaging. Simultaneously, we improved the resolution of the defocus area by modifying a prior work of back-projection (BP) reconstruction algorithm typically used in point-focused transducer based PAE and applying it to line-focused PA/USE. This combined approach may significantly enhance the depth of field of ultrasonic imaging and the resolution of the defocus zone in PA/US imaging, compared to the conventional method. Sufficient numerical simulations and phantom experiments were performed to verify this method. The results show that our method can effectively improve the lateral resolution in the image's defocused region to achieve automatic focusing and perfectly solve the defect of the target signal difference in the far-focus region in ultrasonic imaging, while also enhancing the image SNR and contrast. The proposed method in this paper lays foundations for the realization of photoacoustic/ultrasonic combined endoscopy with enhanced lateral resolution and depth of field, which can potentially benefit a many of biomedical applications.

Indexed as

acoustic resolution photoacoustic/ultrasonic endoscopy (PA/USE)imaging depth of fieldimproved back-projection imaging algorithmline-focused transducerphotoacoustic imaging (PAI)ultrasonic imaging (USI)

Identifiers

PMID35071214
PMCPMC8770734
OpenAlexW4206324012

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.