Multicenter comparative study of three "non-destructive" methods of detecting the cleanliness of the da Vinci surgical robotic instrument.

Aiqin Chen, Xiumei Zou, Yanhua Tan, Yanhan Chen, Xinru Ye, Shuqin Hao

Abstract read
In one paragraph

Article in Gland surgery, 2021. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 3 papers.

0numbers the graph read from it
0cells of the map it votes in
3citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

3 citing papers in PubMed.

  1. Article
  2. Article
  3. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors.

Aiqin Chen *Central Sterile Supply Department, Sun Yat-sen University Cancer Center, Guangzhou, China.
Xiumei Zou *Intensive Care Unit, Sun Yat-sen University Cancer Center, Guangzhou, China.
Yanhua TanCentral Sterile Supply Department, First Affiliated Hospital of Guangzhou Medical University, Guangzhou, China.
Yanhan ChenCentral Sterile Supply Department, Sun Yat-sen University Cancer Center, Guangzhou, China.
Xinru YeCentral Sterile Supply Department, Sun Yat-sen University Cancer Center, Guangzhou, China.
Shuqin HaoCentral Sterile Supply Department, Shenzhen Second People's Hospital, Shenzhen, China.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

backgroundThe robotic instrument of the da Vinci surgical system determines the accuracy of robotic-assisted surgery, However, the most effective cleaning method of robotic equipment is a challenge for healthcare professionals. This study compared three da Vinci robot-assisted surgery manipulators to detect the effect of "non-destructive" testing of the cleaning effect by two different methods.

methodsThe post-surgical cleaning of the da Vinci robotic instruments in the Sun Yat-sen University Cancer Center, The First Affiliated Hospital of Guangzhou Medical University and the Shenzhen Second People's Hospital was performed using two different processes from January 2019 to January 2020: manual joint automatic ultrasonic cleaning and automatic mechanical cleaning. The efficacy of visual estimation, the residual protein assay (quantitative) and adenosine triphosphate (ATP) biological biofluorescence detection of the cleanliness of the mechanical instrument's work (distal working end) surface and the shaft's inner chamber was compared. If the cleaning effect of any position on the surface or inner cavity of the manipulator did not qualify, the entire robotic instrument was judged as disqualified.

resultsA total of 198 cases of da Vinci robotic instrument postoperative cleanliness data were collected. The qualifying rates of automatic ultrasonic cleaning were 96.97% by visual estimation, 93.94% by residual protein assay and 60.61% by ATP biological fluorescence detection. The respective rates for automatic mechanical cleaning were 100% by visual estimation, 90.91% by residual protein assay and 66.67% by ATP biological fluorescence detection.

conclusionsThe cleaning of the da Vinci robotic instrument detected by "non-destructive" residual protein assay or ATP biological fluorescence detection is more accurate than visual estimation.

Indexed as

Adenosine triphosphate (ATP) assaycleanliness testingDa Vinci robotic surgical instrumentsresidual protein assayvisual estimation

Identifiers

PMID35070890
PMCPMC8749094

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.